University of Adelaide Library

Adelaide Research and Scholarship : Theses : Research Theses

Please use this identifier to cite or link to this item: http://hdl.handle.net/2440/37817

Type: Thesis
Title: Modelling the impact of treatment uncertainties in radiotherapy
Author: Booth, Jeremy T
Issue Date: 2002
School/Discipline: Department of Physics and Mathematical Physics
Abstract: Uncertainties are inevitably part of the radiotherapy process. Uncertainty in the dose deposited in the tumour exists due to organ motion, patient positioning errors, fluctuations in machine output, delineation of regions of interest, the modality of imaging used, and treatment planning algorithm assumptions among others; there is uncertainty in the dose required to eradicate a tumour due to interpatient variations in patient-specific variables such as their sensitivity to radiation; and there is uncertainty in the dose-volume restraints that limit dose to normal tissue. This thesis involves three major streams of research including investigation of the actual dose delivered to target and normal tissue, the effect of dose uncertainty on radiobiological indices, and techniques to display the dose uncertainty in a treatment planning system. All of the analyses are performed with the dose distribution from a four-field box treatment using 6 MV photons. The treatment fields include uniform margins between the clinical target volume and planning target volume of 0.5 cm, 1.0 cm, and 1.5 cm. The major work is preceded by a thorough literature review on the size of setup and organ motion errors for various organs and setup techniques used in radiotherapy. A Monte Carlo (MC) code was written to simulate both the treatment planning and delivery phases of the radiotherapy treatment. Using MC, the mean and the variation in treatment dose are calculated for both an individual patient and across a population of patients. In particular, the possible discrepancy in tumour position located from a single CT scan and the magnitude of reduction in dose variation following multiple CT scans is investigated. A novel convolution kernel to include multiple pretreatment CT scans in the calculation of mean treatment dose is derived. Variations in dose deposited to prostate and rectal wall are assessed for each of the margins and for various magnitudes of systematic and random error, and penumbra gradients. The linear quadratic model is used to calculate prostate Tumour Control Probability (TCP) incorporating an actual (modelled) delivered prostate dose. The Kallman s-model is used to calculate the normal tissue complication probability (NTCP), incorporating actual (modelled) fraction dose in the deforming rectal wall. The impact of each treatment uncertainty on the variation in the radiobiological index is calculated for the margin sizes.
Advisor: Zavgorodni, Sergei F.
Patterson, John
Dissertation Note: Thesis (Ph.D.)--Department of Physics and Mathematical Physics, 2002.
Keywords: radiotherapy, dose uncertainty, Monte Carlo, dose delivery
Appears in Collections:Research Theses

Files in This Item:

File Description SizeFormat
01front.pdf288.59 kBAdobe PDFView/Open
02chapter1.pdf119.46 kBAdobe PDFView/Open
03chapter2.pdf553.61 kBAdobe PDFView/Open
04chapter3.pdf678.38 kBAdobe PDFView/Open
05chapter4.pdf974.07 kBAdobe PDFView/Open
06chapter5.pdf555.38 kBAdobe PDFView/Open
07chapter6.pdf562.26 kBAdobe PDFView/Open
08chapter7.pdf545.47 kBAdobe PDFView/Open
09chapter8.pdf92.82 kBAdobe PDFView/Open
10appendix.pdf3.65 MBAdobe PDFView/Open
11bibliog.pdf193.72 kBAdobe PDFView/Open

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

© 2008 The University of Adelaide
library@adelaide.edu.au
CRICOS Provider Number 00123M
Service Charter | Copyright | Privacy | Disclaimer