Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/53598
Citations
Scopus Web of ScienceĀ® Altmetric
?
?
Type: Journal article
Title: Sleeve sphincter of Oddi (SO) manometry: a new method for characterizing the motility of the sphincter of Oddi
Author: Kawamoto, M.
Geenen, J.
Omari, T.
Schloithe, A.
Saccone, G.
Toouli, J.
Citation: Journal of Hepato-Biliary-Pancreatic Surgery, 2008; 15(4):391-396
Publisher: Springer Tokyo
Issue Date: 2008
ISSN: 0944-1166
1436-0691
Statement of
Responsibility: 
Masahiko Kawamoto, Joseph Geenen, Taher Omari, Ann C. Schloithe, Gino T. P. Saccone and James Toouli
Abstract: Background/Purpose Perfused multilumen sphincter of Oddi (SO) manometry is accepted as the gold standard for diagnosis of SO dysfunction. However, this technique is associated with a relatively high incidence of post-procedure acute pancreatitis. In addition, triple-lumen manometry recordings may be difficult to interpret, as movement may produce artifacts. We have refined the development of a sleeve sensor for human SO manometry. This assembly aims to overcome the above limitations. In this study the accuracy of sleeve SO manometry (SOM) has been evaluated and compared with standard triple-lumen perfused SOM. Methods Patients undergoing SO manometric studies consented to having both standard triple-lumen and sleeve SOM. A total of 32 paired studies were performed in 29 patients. Diagnosis was made only from standard triple-lumen SOM and the patient treated accordingly. For each study, SO basal pressure, contraction, amplitude, and frequency were recorded. Results There was no statistically significant difference in the recordings of SO basal pressure, contraction, amplitude, and frequency between the two techniques. A strong correlation was demonstrated between SO basal pressure determined with the two catheters. The accuracy of sleeve SOM is comparable to standard triple-lumen SOM, with less movement artifact. One patient developed mild post-manometric pancreatitis. Conclusions The sleeve catheter records SO pressures with comparable values to standard triple-lumen SOM. The sleeve assembly potentially can replace the use of the perfused triple-lumen catheter for the objective diagnosis of SO dysfunction.
Keywords: Sphincter of Oddi
Manometry
Sleeve assembly
Description: The original publication can be found at www.springerlink.com
DOI: 10.1007/s00534-007-1262-1
Published version: http://dx.doi.org/10.1007/s00534-007-1262-1
Appears in Collections:Aurora harvest
Paediatrics publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.