Abstract: This paper presents results of an experimental study on the behavior of square and rectangular high-strength concrete (HSC)-filled fiber-reinforced polymer (FRP) tubes (HSCFFT) under concentric compression. The effects of the tube thickness, sectional aspect ratio, and corner radius on the axial compressive behavior of concrete-filled FRP tubes (CFFT) were investigated experimentally through the tests of 24 CFFTs that were manufactured using unidirectional carbon fiber sheets and high-strength concrete with 78 MPa average compressive strength. As the first experimental investigation on the axial compressive behavior of square and rectangular HSCFFTs, the results of the study reported in this paper allow a number of significant conclusions to be drawn. First and foremost, test results indicate that sufficiently confined square and rectangular HSCFFTs can exhibit highly ductile behavior. The results also indicate that confinement effectiveness of FRP tubes increases with an increase in corner radius and decreases with an increase in sectional aspect ratio. It is also observed and discussed that HSCFFTs having tubes of low confinement effectiveness may experience a significant strength loss at the point of transition on their stress-strain curves. Furthermore, it is found that the behavior of HSCFFTs at this region differ from that of normal-strength CFFTs and that it is more sensitive to the effectiveness of a confining tube. Examination of the test results have also lead to a number of important observations on the influence of the key confinement parameters on the development and distribution of the hoop strains on the tubes of CFFTs, which are presented and discussed in the paper. © 2013 American Society of Civil Engineers.
Keywords: Fiber reinforced polymer
High-strength concrete
Concrete columns
Tubes
Stress strain relations
Confinement
Compressive strength.
Rights: © 2013 American Society of Civil Engineers
DOI: 10.1061/(ASCE)CC.1943-5614.0000321
Published version: http://dx.doi.org/10.1061/(asce)cc.1943-5614.0000321
Appears in Collections:Aurora harvest
Civil and Environmental Engineering publications

Files in This Item:
File Description SizeFormat 
hdl_78562.pdfAccepted version5.05 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.