Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/101217
Citations
Scopus Web of Science® Altmetric
?
?
Full metadata record
DC FieldValueLanguage
dc.contributor.authorStanwix, P.L.-
dc.contributor.authorTobar, M.E.-
dc.contributor.authorWinterflood, J.-
dc.contributor.authorIvanov, E.N.-
dc.contributor.authorSusli, M.-
dc.contributor.authorHartnett, J.G.-
dc.contributor.authorVan Kann, F.-
dc.contributor.authorWolf, P.-
dc.date.issued2005-
dc.identifier.citationProceedings of the 2004 IEEE International Frequency Control Symposium and Exposition, 2005, pp.757-761-
dc.identifier.isbn0780384148-
dc.identifier.isbn9780780384149-
dc.identifier.issn1075-6787-
dc.identifier.urihttp://hdl.handle.net/2440/101217-
dc.description.abstractRecent experiments based on cryogenic microwave oscillators [1,2,3] have tested the isotropy of the speed of light (Michelson-Morley experiment) at sensitivities of the order of a part in 1015, which is a similar sensitivity to other best tests [4,5]. Further improvements of the accuracy in this type of experiment are not expected due to the already long data set and the systematic error limit [3]. We have constructed a new rotating Michelson-Morley experiment consisting of two cylindrical cryogenic sapphire resonators. The temperature of the dual cavity is controlled at approximately 6 K where the beat frequency between two oscillators is independent on temperature. By rotating the experiment an improvement of several orders of magnitude in our sensitivity to light speed anisotropy is expected, as the relevant time variations will now be at the rotation frequency where the frequency stability of the cryogenic oscillators is the best.-
dc.description.statementofresponsibilityP.L. Stanwix, M.E. Tobar, M. Susli, C.R. Locke, E.N. Ivanov, J. Winterflood, J.G. Hartnett, F. van Kann, P. Wolf-
dc.language.isoen-
dc.publisherIEEE-
dc.rights© 2004 IEEE.-
dc.source.urihttp://dx.doi.org/10.1109/freq.2004.1418561-
dc.subjectMichelson-Morley; Crypgenic Sapphire Oscillator; Dual Cavity-
dc.titleRotating Michelson-Morley experiment based on a dual cavity cryogenic sapphire oscillator-
dc.typeConference paper-
dc.contributor.conferenceIEEE International Frequency Control Symposium and Exposition, 2004 (23 Aug 2004 - 27 Aug 2004 : Montréal, Québec)-
dc.identifier.doi10.1109/FREQ.2004.1418561-
dc.publisher.placePiscataway, N.J.-
pubs.publication-statusPublished-
Appears in Collections:Aurora harvest 7
IPAS publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.