Title: Adjustment of anterior corneal astigmatism values to incorporate the likely effect of posterior corneal curvature for toric intraocular lens calculation
Author: Goggin, M.
Zamora-Alejo, K.
Esterman, A.
van Zyl, L.
Citation: Journal of Refractive Surgery, 2015; 31(2):98-102
Publisher: Healio
Issue Date: 2015
ISSN: 1081-597X
1938-2391
Statement of
Responsibility: 
Michael Goggin, Katherine Zamora-Alejo, Adrian Esterman, Lourens van Zyl
Abstract: PURPOSE: To establish if average refractive overcorrection or undercorrection of corneal astigmatism based on the “rule” of the astigmatism occurs if toric intraocular lenses (IOLs) are calculated on the basis of anterior corneal measurements, and to calculate an adjustment for individual eyes to avoid this systematic error. METHODS: One hundred forty-three consecutive eyes of 115 patients underwent phacoemulsification with IOL powers calculated using anterior corneal curvature data alone. Eyes were grouped as either “with-the-rule” or “against-the-rule” on the basis of the steep anterior corneal meridian. Targeted versus achieved astigmatic outcomes were compared. Main outcome measure was residual refractive astigmatism following the insertion of a toric IOL due to the likely effect of posterior corneal astigmatism. RESULTS: Significant prediction errors in astigmatic outcome occurred only with IOL cylinders of 2 diopters or less. Overcorrection occurred by a factor of 1.38 in with-the-rule eyes and undercorrection occurred by a factor of 0.65 in against-the-rule eyes. CONCLUSIONS: A coefficient of adjustment of 0.75 for with-the-rule eyes and 1.41 for against-the-rule eyes can be applied to the corneal astigmatism power value to calculate a more appropriate IOL cylinder power than that calculated by using unadjusted anterior corneal curvature measurements. These adjustment coefficients apply only to those eyes that would have received IOLs with 2 diopters of cylinder or less and calculated with such unadjusted measurements. Greater IOL cylinder powers are sufficiently accurately calculated using unadjusted values.
Keywords: Cornea; Humans; Astigmatism; Phacoemulsification; Lens Implantation, Intraocular; Nomograms; Retrospective Studies; Lenses, Intraocular; Biometry
Rights: Copyright © SLACK Incorporated
RMID: 0030041241
DOI: 10.3928/1081597X-20150122-04
Appears in Collections:Medicine publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.