Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/10589
Citations
Scopus Web of Science® Altmetric
?
?
Type: Journal article
Title: Detection of bile reflux: in vivo validation of the Bilitec fibreoptic system
Author: Barrett, M.
Myers, J.
Watson, D.
Jamieson, G.
Citation: Diseases of the Esophagus, 2000; 13(1):44-50
Publisher: Blackwell Publishing Asia
Issue Date: 2000
ISSN: 1120-8694
1442-2050
Statement of
Responsibility: 
M. W. Barrett, J. C. Myers, D. I. Watson and G. G. Jamieson
Abstract: The Bilitec ambulatory bile reflux monitor is advocated for the assessment of bile reflux. However, it has only been validated by bench top (in vitro) studies. This in vivo study used controlled ‘iatrogenic’ episodes of bile reflux to determine the ability of the Bilitec system to detect bile acids in the oesophageal lumen. At least 10 ml of fluid was aspirated from the stomach of each of 32 patients, and analysed quantitatively for total bile acids (TBA) and total bilirubin (TB). An in vitro assessment of this fluid with the Bilitec probe was performed initially. The Bilitec probe was then sited in the distal oesophagus, and the gastric fluid was introduced into the mid-oesophagus, through a naso-oesophageal tube, as a series of 10-ml volumes of varying dilutions (1:8, 1:4, 1:2, undiluted) to simulate gastro-oesophageal reflux events. Intraoesophageal bilirubin absorbance was compared with TBA and TB for each dilution. Both TBA and TB values correlated strongly with bilirubin absorbance in vitro (r=0.83, p < 0.0001 and r=0.82, p < 0.0001 respectively). However, this relationship was weaker in vivo (r=0.64, p=0.0001 and r=0.68, p < 0.0001 respectively). Of the dilutions which contained potentially injurious concentrations of bile acid (>1 mmol/L), 77% were associated with absorbance >0.14 (currently accepted absorbance threshold for oesophageal bile reflux). Although in vitro sensitivity of the Bilitec probe to bile acids was excellent, in vivo sensitivity was less reliable, and 23% of significant ‘bile reflux’ episodes did not exceed the currently recommended Bilitec absorbance threshold for bile reflux. In contrast, false-positive results were unlikely. These findings suggest that the overall accuracy of the Bilitec system is probably sufficient for clinical use, although this method is not sufficiently reliable to be regarded as the gold standard for the evaluation of duodeno-oesophageal reflux.
Keywords: Humans
Bile Reflux
Monitoring, Ambulatory
Adult
Aged
Aged, 80 and over
Middle Aged
Female
Male
Fiber Optic Technology
DOI: 10.1046/j.1442-2050.2000.00062.x
Published version: http://dx.doi.org/10.1046/j.1442-2050.2000.00062.x
Appears in Collections:Aurora harvest 2
Surgery publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.