Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/23474
Citations
Scopus Web of Science® Altmetric
?
?
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGentilcore, D.-
dc.contributor.authorHausken, T.-
dc.contributor.authorHorowitz, M.-
dc.contributor.authorJones, K.-
dc.date.issued2006-
dc.identifier.citationNeurogastroenterology and Motility, 2006; 18(12):1062-1068-
dc.identifier.issn1350-1925-
dc.identifier.issn1365-2982-
dc.identifier.urihttp://hdl.handle.net/2440/23474-
dc.descriptionThe definitive version is available at www.blackwell-synergy.com-
dc.description.abstractScintigraphy represents the 'gold standard' for the measurement of gastric emptying. Recent studies suggest that three-dimensional (3D) ultrasonography may allow a precise measure of gastric emptying, given the capacity for accurate volume calculations of the stomach. The aim of this study was to compare measurements of gastric emptying of both low- and high-nutrient drinks by 3D ultrasonography with scintigraphy. Ten healthy young subjects (6M, 4F, age 23.5 ± 1.5 years) were studied on 2 days. Concurrent measurements of gastric emptying by scintigraphy and 3D ultrasonography were performed after ingestion of 500 mL beef soup (12 kcal) or 300 ml dextrose (25% w/v) (314 kcal) labelled with 20 MBq 99mTc-sulphur colloid. There was no significant difference between scintigraphic and ultrasonographic 50% emptying times (T50s) (soup: 27.7 ± 4.8 min vs 23.8. ± 4.8 min; dextrose: 122.2 ± 13.3 min vs 131.9 ± 10.2 min). There was a close correlation between scintigraphic and ultrasonographic T50s for both soup (r ¼ 0.92, P ¼ 0.0005) and dextrose (r ¼ 0.88, P ¼ 0.0007). For the T50s, the limits of agreement were )15.2 min and +8.1 min for the soup (mean difference)3.6 min) and )35.3 min and +47.6 min for dextrose (mean difference +6.2 min). 3D ultrasonography provides a valid measure of gastric emptying of liquid meals in healthy subjects.-
dc.description.statementofresponsibilityD. Gentilcore, T. Hausken, M. Horowitz & K. L. Jones-
dc.language.isoen-
dc.publisherBlackwell Publishing Ltd-
dc.source.urihttp://dx.doi.org/10.1111/j.1365-2982.2006.00830.x-
dc.subjectreal-time ultrasound-
dc.subject3-dimensional ultrasonography-
dc.subjectfunctional dyspepsia-
dc.subjectintragastric distribution-
dc.subjectantroduodenal motility-
dc.subjectnonulcer dyspepsia-
dc.subjecttranspyloric flow-
dc.subjectvolume estimation-
dc.subjectproximal stomach-
dc.subjectin-vivo-
dc.titleMeasurements of gastric emptying of low- and high-nutrient liquids using 3D ultrasonography and scintigraphy in healthy subjects-
dc.typeJournal article-
dc.identifier.doi10.1111/j.1365-2982.2006.00830.x-
pubs.publication-statusPublished-
dc.identifier.orcidHorowitz, M. [0000-0002-0942-0306]-
dc.identifier.orcidJones, K. [0000-0002-1155-5816]-
Appears in Collections:Aurora harvest 6
Medicine publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.