dc.identifier.citationAcoustics 2002 [electronic resource] : innovation in acoustics and vibration : [proceedings of] the Annual Conference of the Australian Acoustical Society, 13-15 November, 2002 / Anthony Zander (ed.): pp.8-15-
dc.identifier.isbn0909882193-
dc.identifier.urihttp://hdl.handle.net/2440/28734-
dc.description.abstractTonal noise radiated from an exhaust stack of a spray dryer system used to make powdered milk has been the source of unwanted community noise.The tone is characterised by a frequency above the first mode cut-on frequency of the exhaust duct and it is not steady in either amplitude or frequency. Passive silencing of the exhaust is a very expensive and inconvenient option and for this reason the feasibility of using active noise control was investigated. Zander and Hansen developed a theoretical model for analysing the effect of active noise control on higher order rectangular duct modes,and used it to evaluate the effects of source size,location and strength. It was shown that the total acoustic power reduction was dependent on the relative locations of the control sources. More recently this work was applied to the practical example of a cylindrical spray dryer exhaust stack to determine the most suitable location and number of control sources and error sensors. Prior to installation in the exhaust stack a half scale model was constructed to test the theory. Here, the effect of the error sensor locations on the active control on higher order acoustic modes propagating in the half scale circular duct is investigated experimentally using real time control with a multi-channel feedforward controller. A tachometer signal at the fan blade pass frequency (BPF) was fed into the controller as the reference signal for the feedforward control. Two configurations of error sensors on the duct wall were tested to evaluate how the error sensor locations affect the control performance, which was evaluated in the far field of the duct outlet.-
dc.description.statementofresponsibilityXun Li, Colin D. Kestell, Xiaojun Qiu, Anthony C. Zander and Colin H. Hansen-
dc.language.isoen-
dc.publisherAustralian Acoustical Society-
dc.source.urihttp://www.mecheng.adelaide.edu.au/avc/publications/abstract.php?abstract=117-
dc.titleExperimental study of active control of high order acoustic modes in ducts-
dc.typeConference paper-
dc.contributor.conferenceAnnual Conference of the Australian Acoustical Society (2002 : Adelaide, South Australia)-
dc.publisher.placeC/o Professional Centre, Private Bag 1, Darlinghurst 2010-
pubs.publication-statusPublished-
dc.identifier.orcidZander, A. [0000-0003-4099-8146]-
dc.identifier.orcidHansen, C. [0000-0002-1444-4716]-
Appears in Collections:Aurora harvest 6
Environment Institute publications
Mechanical Engineering conference papers

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.