Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/35273
Citations
Scopus Web of Science® Altmetric
?
?
Full metadata record
DC FieldValueLanguage
dc.contributor.authorWong, K.-
dc.contributor.authorKuklik, P.-
dc.contributor.authorKelso, R.-
dc.contributor.authorWorthley, S.-
dc.contributor.authorSanders, P.-
dc.contributor.authorMazumdar, J.-
dc.contributor.authorAbbott, D.-
dc.contributor.editorNicolau, D.V.-
dc.date.issued2006-
dc.identifier.citationBiomedical applications of micro- and nanoengineering III : 11-13 December 2006, Adelaide, Australia / Dan V. Nicolau (ed.): pp. 1-12-
dc.identifier.isbn0819465240-
dc.identifier.isbn9780819465245-
dc.identifier.issn0277-786X-
dc.identifier.issn1996-756X-
dc.identifier.urihttp://hdl.handle.net/2440/35273-
dc.description.abstractThis study describes an application based on the optical flow algorithm to construct a 2D velocity field plot. The estimated velocity field is used to track the movement of blood in real time. This methodology has been applied to medical images to quantify blood flow turbulence in the right atrium of the heart. Blood intensity fields that are obtained from clinical MRI scan sequences can be analyzed using this method. Septal defects and other heart diseases can be assessed for degrees of abnormality and post-surgical success can be evaluated. We have developed this technique specifically for characterizing the turbulence generated due to such heart abnormalities. The degree of turbulence and fluid shear stress can be determined from the measured flow field. The cardio dynamics information that is based on flow analysis and visualization of blood offers potential for the detection and quantification of myocardial malfunctioning.-
dc.description.statementofresponsibilityK. Wong; P. Kuklik; R. M. Kelso; S. G. Worthley; P. Sanders; J. Mazumdar; D. Abbott-
dc.language.isoen-
dc.publisherSPIE-
dc.relation.ispartofseriesProceedings of SPIE ; 6416-
dc.rights© 2006 Society of Photo-Optical Instrumentation Engineers.-
dc.source.urihttp://spie.org/x648.xml?product_id=696691-
dc.titleBlood flow assessment in a heart with a septal defect based on optical flow analysis of magnetic resonance images-
dc.typeConference paper-
dc.contributor.conferenceBiomedical Applications of Micro- and Nanoengineering (3rd : 2006 : Adelaide, Australia)-
dc.identifier.doi10.1117/12.696691-
dc.publisher.placeUSA-
pubs.publication-statusPublished-
dc.identifier.orcidKuklik, P. [0000-0001-8440-654X]-
dc.identifier.orcidKelso, R. [0000-0002-5783-9232]-
dc.identifier.orcidSanders, P. [0000-0003-3803-8429]-
dc.identifier.orcidAbbott, D. [0000-0002-0945-2674]-
Appears in Collections:Aurora harvest
Electrical and Electronic Engineering publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.