Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/35676
Citations
Scopus Web of Science® Altmetric
?
?
Type: Journal article
Title: The margin of safety of a left double-lumen tracheobronchial tube depends on the length of the bronchial cuff and tip
Author: Partridge, L.
Russell, W.
Citation: Anaesthesia and Intensive Care, 2006; 34(5):618-620
Publisher: Australian Soc Anaesthetists
Issue Date: 2006
ISSN: 0310-057X
1448-0271
Statement of
Responsibility: 
L. Partridge, W. J. Russell
Abstract: The left tracheobronchial double-lumen tube is the commonest device to separate the left and right lungs for differential ventilation. With the appropriate tube, the left bronchial cuff is positioned in the bronchus so that the cuff is beyond the carina but the tip of the tube does not occlude the aperture of the left upper lobe bronchus. The difference between the length of the left main bronchus and the length of the cuff and tip of the bronchial segment of the tube has been termed 'the margin of safety' by Benumof. If the length of the cuff plus the tip exceeds that of the left main bronchus, there will be occlusion of the left upper lobe bronchus. The bronchial cuff and bronchial tip lengths were measured on two hundred and twenty left tracheobronchial (double-lumen) tubes from four manufacturers. The largest cuff–tip length was 40 mm with a Portex 41Fr tube but some 41Fr tubes from all manufacturers had cuff–tip lengths of 33 mm or greater which exceed the length of the shortest left main bronchus measured by Benumof. There was also a marked variation in cuff–tip lengths of the same size tube from the same manufacturer. The largest variation was 18 mm for the Portex 41 but substantial variation of 8 mm or more was found in at least one French size of all manufacturers. Users must be aware that significant cuff–tip length variation occurs and match the selected tube to the patient to ensure an adequate margin of safety.
Keywords: Bronchi
Trachea
Humans
Reproducibility of Results
Intubation, Intratracheal
Description: Publisher's copy made available with the permission of the publisher © Australian Society of Anaesthetists
DOI: 10.1177/0310057x0603400513
Description (link): http://www.aaic.net.au/Article.asp?D=2006002
Published version: http://dx.doi.org/10.1177/0310057x0603400513
Appears in Collections:Anaesthesia and Intensive Care publications
Aurora harvest 6

Files in This Item:
File Description SizeFormat 
hdl_35676.pdf152.13 kBPublisher's PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.