Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/45035
Citations
Scopus Web of Science® Altmetric
?
?
Full metadata record
DC FieldValueLanguage
dc.contributor.authorWong, K.-
dc.contributor.authorKelso, R.-
dc.contributor.authorWorthley, S.-
dc.contributor.authorSanders, P.-
dc.contributor.authorMazumdar, J.-
dc.contributor.authorAbbott, D.-
dc.contributor.editorDerek Abbott,-
dc.date.issued2007-
dc.identifier.citationComplex Systems II / Derek Abbott, Tomaso Aste, Murray Batchelor, Robert Dewar, Tiziana Di Matteo, Tony Guttmann (eds.):68021H-1-68021H-10-
dc.identifier.isbn9780819469731-
dc.identifier.issn0277-786X-
dc.identifier.issn1996-756X-
dc.identifier.urihttp://hdl.handle.net/2440/45035-
dc.descriptionCopyright 2007 Society of Photo-Optical Instrumentation Engineers. This paper was published in Complex Systems II, edited by Derek Abbott, Tomaso Aste, Murray Batchelor, Robert Dewar, Tiziana Di Matteo, Tony Guttmann, Proc. of SPIE Vol. 6802, 68021H and is made available as an electronic reprint with permission of SPIE. One print or electronic copy may be made for personal use only. Systematic or multiple reproduction, distribution to multiple locations via electronic or other means, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper are prohibited.-
dc.description.abstractA recent development based on optical flow applied onto Fast Imaging in Steady State Free Precession (TrueFISP) magnetic resonance imaging is able to deliver good estimation of the flow profile in the human heart chamber. The examination of cardiac flow based on tracking of MR signals emitted by moving blood is able to give medical doctors insight into the flow patterns within the human heart using standard MRI procedure without specifically subjecting the patient to longer scan times using more dedicated scan protocols such as phase contrast MRI. Although MR fluid motion estimation has its limitations in terms of accurate flow mapping, the use of a comparatively quick scan procedure and computational post-processing gives satisfactory flow quantification and can assist in management of cardiac patients. In this study, we present flow in the left atria of five human subjects using MR fluid motion tracking. The measured flow shows that vortices exist within the atrium of heart. Although the scan is two-dimensional, we have produced multiple slices of flow maps in a spatial direction to show that the vortex exist in a three-dimensional space.-
dc.description.statementofresponsibilityKelvin K. L. Wong, Richard M. Kelso, Stephen M. Worthley, Prash Sanders, Jagannath Mazumdar, Derek Abbott-
dc.language.isoen-
dc.publisherSPIE-
dc.relation.ispartofseriesProceedings of SPIE ; 6802-
dc.rightsCopyright © 2008 SPIE - The International Society for Optical Engineering.-
dc.source.urihttp://dx.doi.org/10.1117/12.787253-
dc.titleFlow in left atrium using MR fluid motion estimation-
dc.typeConference paper-
dc.contributor.conferenceMicroelectronics, MEMS, and Nanotechology (2007 : Canberra, Australia)-
dc.identifier.doi10.1117/12.787253-
dc.publisher.placeCDROM-
pubs.publication-statusPublished-
dc.identifier.orcidKelso, R. [0000-0002-5783-9232]-
dc.identifier.orcidSanders, P. [0000-0003-3803-8429]-
dc.identifier.orcidAbbott, D. [0000-0002-0945-2674]-
Appears in Collections:Aurora harvest 6
Electrical and Electronic Engineering publications

Files in This Item:
File Description SizeFormat 
hdl_45035.pdf581.83 kBPublisher's PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.