Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/45307
Citations
Scopus Web of Science® Altmetric
?
?
Type: Journal article
Title: Escherichia coli biotin protein ligase: characterization and development of a high-throughput assay
Author: Ng, B.
Polyak, S.
Bird, D.
Bailey, L.
Wallace, J.
Booker, G.
Citation: Analytical Biochemistry, 2008; 376(1):131-136
Publisher: Academic Press Inc Elsevier Science
Issue Date: 2008
ISSN: 0003-2697
1096-0309
Statement of
Responsibility: 
Belinda Ng, Steven W. Polyak, Daniel Bird, Lisa Bailey, John C. Wallace and Grant W. Booker
Abstract: The rapid rise in pathogenic bacteria resistant to current treatments, coupled with the paucity of new therapeutic agents in the pipeline, has resulted in a significant need for new antibiotics. One strategy to overcome resistance requires new chemical entities that inhibit key enzymes in essential metabolic processes that have not been previously targeted and for which there is no preexisting drug resistance. Biotin protein ligase (BPL), required to complete acetyl CoA carboxylase's capability for fatty acid biosynthesis, is one target that has not yet been fully explored. However, its application in large-scale compound screens has been limited due to the lack of a truly high-throughput assay for enzyme activity. Here we report a novel assay system for BPL from Escherichia coli (BirA). This assay employs fluorescence polarization technology together with a unique peptide substrate for BirA. Additionally, the multiple handling steps and requirement for radiolabeled ligands associated with previous assays have been eliminated. Kinetic analysis of MgATP (K(m) 0.25+/-0.01 mM) and biotin (K(m) 1.45+/-0.15 microM) binding produced results consistent with published data. Inhibition studies with end products of the BPL reaction, AMP and pyrophosphate, further validated the assay. Statistical analysis, performed upon both intraassay and interassay results (n = 30), showed the coefficient of variance to be <10% across all data sets. Furthermore, Z' factors between 0.5 and 0.8 demonstrated the utility of this technology in high-throughput applications.
Keywords: Carbon-Nitrogen Ligases
Escherichia coli Proteins
Repressor Proteins
Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization
Substrate Specificity
Kinetics
Chemistry Techniques, Analytical
Rights: © 2008 Elsevier Inc. All rights reserved.
DOI: 10.1016/j.ab.2008.01.026
Published version: http://dx.doi.org/10.1016/j.ab.2008.01.026
Appears in Collections:Aurora harvest
Molecular and Biomedical Science publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.