Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/63496
Citations
Scopus Web of Science® Altmetric
?
?
Type: Journal article
Title: Measurement of gastric emptying of a high-nutrient liquid by 3D ultrasonography in diabetic gastroparesis
Author: Stevens, J.
Gilja, O.
Gentilcore, D.
Hausken, T.
Horowitz, M.
Jones, K.
Citation: Neurogastroenterology and Motility, 2011; 23(3):220-e114
Publisher: Blackwell Publishing Ltd
Issue Date: 2011
ISSN: 1350-1925
1365-2982
Statement of
Responsibility: 
J. E. Stevens, O. H. Gilja, D. Gentilcore, T. Hausken, M. Horowitz & K. L. Jones
Abstract: <h4>Background</h4>Gastric emptying (GE) is delayed in 30-50% of patients with longstanding diabetes. Scintigraphy represents the 'gold standard' for measurement of GE, but is associated with a radiation burden. Three-dimensional (3D) ultrasonography has recently been demonstrated to provide a valid measure of liquid GE in healthy subjects; however, the technique has not been validated in patients with gastroparesis. The primary aim of this study was to compare measurements of GE of a high-nutrient glucose drink by 3D ultrasonography and scintigraphy in diabetic gastroparesis.<h4>Methods</h4>Ten patients (eight type 1, two type 2, 6M, 4F, aged 46.1 ± 4.5 years, BMI 29.1 ± 1.6 kg m(-2), duration 19.6 ± 3.3 years) with diabetic gastroparesis [defined as retention at 100 min of solid (100 g minced beef) ≥ 61% and/or 50% emptying time (T50) of liquid (150 mL 10% dextrose) ≥ 31 min], were studied. Concurrent measurements of GE by scintigraphy and 3D ultrasonography were performed following ingestion of 75 g glucose in 300 mL water labeled with 20 MBq (99m) Tc-sulfur colloid.<h4>Key results</h4>There was no significant difference in GE between the two techniques (T50s: scintigraphy - 103.3 ± 10.0 min VS 3D ultrasonography - 98.8 ± 10.4 min; P = 0.60). There was a significant correlation between scintigraphic and ultrasonographic T50s (r = 0.67, P = 0.03). The limits of agreement for the T50s were -57.22 min and +48.22 min (mean difference -4.5 min). Blood glucose after the drink was greater when GE was relatively more rapid (e.g. at t = 60 min; scintigraphy: r = -0.65, P = 0.04; 3D ultrasonography: r = -0.78, P = 0.008).<h4>Conclusions & inferences</h4>Three-dimensional ultrasonography appears to provide a valid, and non-invasive, measure of GE of high-nutrient liquids in diabetic gastroparesis.
Keywords: diabetes
gastric emptying
gastrointestinal ultrasound
gastroparesis
ultrasonography.
Rights: © 2010 Blackwell Publishing Ltd.
DOI: 10.1111/j.1365-2982.2010.01630.x
Published version: http://dx.doi.org/10.1111/j.1365-2982.2010.01630.x
Appears in Collections:Aurora harvest
Medicine publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.