Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/6708
Citations
Scopus Web of Science® Altmetric
?
?
Full metadata record
DC FieldValueLanguage
dc.contributor.authorField, J.-
dc.contributor.authorHearn, T.-
dc.contributor.authorCosti, J.-
dc.contributor.authorMc Gee, M.-
dc.contributor.authorCosti, K.-
dc.contributor.authorAdachi, N.-
dc.contributor.authorOchi, M.-
dc.date.issued2003-
dc.identifier.citationInjury Extra, 2003; 34(5):334-342-
dc.identifier.issn0020-1383-
dc.identifier.issn1879-0267-
dc.identifier.urihttp://hdl.handle.net/2440/6708-
dc.description© 2002 Elsevier Science Ltd. All rights reserved.-
dc.description.abstractAn ovine model of anterior cruciate ligament reconstruction was utilized to evaluate the biomechanical and histological response of a polylactic acid tibial fixation staple (Gunze Ltd., Japan/Zimmer, Japan). This was performed in a comparison with metallic staples, currently utilized for this procedure. The prosthesis consisted of autograft combined with a Leeds–Keio (L–K) ligament. Early post-operative mobilization was followed by retrieval of specimens at 6, 12 and 24 weeks post-reconstruction. Evaluation of the mechanical characteristics of the graft reconstructions (tensile strength) showed no significant differences (P>0.05) between the staple types for each time period. The histological response to the polylactic acid staple was minimal over the time period studied, with no adverse tissue reactions observed. The mode of reconstruction failure was observed to change with time (P<0.05) presumably as the graft characteristics alter. Overall the absorbable staples performed at a comparable level with the metallic staples within the scope of the study.-
dc.language.isoen-
dc.publisherElsevier Sci Ltd-
dc.source.urihttp://www.journals.elsevierhealth.com/periodicals/jinj/article/PIIS0020138302000128/abstract-
dc.subjectAnterior Cruciate Ligament-
dc.subjectAnimals-
dc.subjectSheep-
dc.subjectLactic Acid-
dc.subjectPolymers-
dc.subjectPolyesters-
dc.subjectPostoperative Period-
dc.subjectProstheses and Implants-
dc.subjectSutures-
dc.subjectTensile Strength-
dc.subjectBiomechanical Phenomena-
dc.titleUltimate tensile strength of a Leeds-Keio/autograft ACL reconstruction utilizing PLLA tibial staple fixation-
dc.typeJournal article-
dc.identifier.doi10.1016/S0020-1383(02)00012-8-
pubs.publication-statusPublished-
dc.identifier.orcidMc Gee, M. [0000-0002-0816-518X]-
Appears in Collections:Aurora harvest
Orthopaedics and Trauma publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.