Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/67141
Citations
Scopus Web of Science® Altmetric
?
?
Type: Journal article
Title: Gastric emptying of a liquid nutrient meal in the critically ill: relationship between scintigraphic and carbon breath test measurement
Author: Chapman, M.
Besanko, L.
Burgstad, C.
Fraser, R.
Bellon, M.
O'Connor, S.
Russo, A.
Jones, K.
Lange, K.
Nguyen, Q.
Bartholomeusz, F.
Chatterton, B.
Horowitz, M.
Citation: Gut, 2011; 60(10):1336-1343
Publisher: British Med Journal Publ Group
Issue Date: 2011
ISSN: 0017-5749
1468-3288
Statement of
Responsibility: 
M J Chapman, L K Besanko, C M Burgstad, R J Fraser, M Bellon, S O’Connor, A Russo, K L Jones, K Lange, N Q Nguyen, F Bartholomeusz, B Chatterton, M Horowitz
Abstract: <h4>Objective</h4>It is assumed that delayed gastric emptying (GE) occurs frequently in critical illness; however, the prevalence of slow GE has not previously been assessed using scintigraphy. Furthermore, breath tests could potentially provide a convenient method of quantifying GE, but have not been validated in this setting. The aims of this study were to (i) determine the prevalence of delayed GE in unselected, critically ill patients and (ii) evaluate the relationships between GE as measured by scintigraphy and carbon breath test.<h4>Design</h4>Prospective observational study.<h4>Setting</h4>Mixed medical/surgical intensive care unit.<h4>Patients</h4>25 unselected, mechanically ventilated patients (age 66 years (49-72); and 14 healthy subjects (age 62 years (19-84)).<h4>Interventions</h4>GE was measured using scintigraphy and (14)C-breath test. A test meal of 100 ml Ensure (standard liquid feed) labelled with (14)C octanoic acid and (99m)Technetium sulphur colloid was placed in the stomach via a nasogastric tube.<h4>Main outcome measures</h4>Gastric 'meal' retention (scintigraphy) at 60, 120, 180 and 240 min, breath test t(50) (BTt(50)), and GE coefficient were determined.<h4>Results</h4>Of the 24 patients with scintigraphic data, GE was delayed at 120 min in 12 (50%). Breath tests correlated well with scintigraphy in both patients and healthy subjects (% retention at 120 min vs BTt(50); r(2)=0.57 healthy; r(2)=0.56 patients; p≤0.002 for both).<h4>Conclusions</h4>GE of liquid nutrient is delayed in approximately 50% of critically ill patients. Breath tests correlate well with scintigraphy and are a valid method of GE measurement in this group.
Keywords: Stomach
Humans
Gastroparesis
Critical Illness
Carbon Dioxide
Carbon Radioisotopes
Technetium Tc 99m Sulfur Colloid
Breath Tests
Radionuclide Imaging
Enteral Nutrition
Follow-Up Studies
Prospective Studies
Exhalation
Gastric Emptying
Adult
Aged
Aged, 80 and over
Middle Aged
Intensive Care Units
Female
Male
Young Adult
Rights: Copyright status unknown
DOI: 10.1136/gut.2010.227934
Published version: http://dx.doi.org/10.1136/gut.2010.227934
Appears in Collections:Aurora harvest 5
Medicine publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.