Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/72090
Citations
Scopus Web of ScienceĀ® Altmetric
?
?
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGong, J.-
dc.contributor.authorSimpson, A.-
dc.contributor.authorLambert, M.-
dc.contributor.authorZecchin, A.-
dc.contributor.authorKim, Y.-
dc.contributor.authorTijsseling, A.-
dc.date.issued2013-
dc.identifier.citationJournal of Pipeline Systems Engineering and Practice, 2013; 4(1):32-40-
dc.identifier.issn1949-1190-
dc.identifier.issn1949-1204-
dc.identifier.urihttp://hdl.handle.net/2440/72090-
dc.descriptionSubmitted: 9 August 2011 Accepted: 16 May 2012 Published: 19 May 2012-
dc.description.abstractA number of different methods that use signal processing of fluid transients (water hammer waves) for fault detection in pipes have been proposed in the past two decades. However, most of them focus solely on the detection of discrete deterioration, such as leaks or discrete blockages. Few studies have been conducted on the detection of distributed deterioration, such as extended sections of corrosion and extended blockages. This is despite the fact that they commonly exist and can have a severe negative impact on the operation of pipelines. The research reported here proposes a method of detecting distributed deterioration by investigating the time-domain water hammer response trace from a single pipe with a deteriorated section. Through wave analysis using a step pressure input, a theoretical square-shaped perturbation is found to exist in the transient pressure trace as a result of distributed deterioration. The hydraulic impedance of this section can be derived from the magnitude of the reflected pressure perturbation, while the location and length of the corresponding deteriorated section can be determined by using the arrival time and duration of the perturbation. The proposed method has been validated by analyzing experimental data measured from a pipe with a section of wall thickness change.-
dc.description.statementofresponsibilityJinzhe Gong, Angus R. Simpson, Martin F. Lambert, Aaron C. Zecchin, Young-il Kim and Arris S. Tijsseling-
dc.language.isoen-
dc.publisherAmerican Society of Civil Engineers-
dc.rightsCopyright 2013 by the American Society of Civil Engineers-
dc.source.urihttp://dx.doi.org/10.1061/(asce)ps.1949-1204.0000111-
dc.subjectPipelines-
dc.subjectFluid transients-
dc.subjectWater distribution systems-
dc.subjectDistributed deterioration-
dc.subjectExtended blockages-
dc.subjectCorrosion-
dc.subjectTime-domain reflectometry-
dc.titleDetection of distributed deterioration in single pipes using transient reflections-
dc.typeJournal article-
dc.identifier.doi10.1061/(ASCE)PS.1949-1204.0000111-
dc.relation.granthttp://purl.org/au-research/grants/arc/DP1095270-
pubs.publication-statusPublished-
dc.identifier.orcidGong, J. [0000-0002-6344-5993]-
dc.identifier.orcidSimpson, A. [0000-0003-1633-0111]-
dc.identifier.orcidLambert, M. [0000-0001-8272-6697]-
dc.identifier.orcidZecchin, A. [0000-0001-8908-7023]-
Appears in Collections:Aurora harvest 2
Civil and Environmental Engineering publications
Environment Institute publications

Files in This Item:
File Description SizeFormat 
hdl_72090.pdfAccepted version363.88 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.