Please use this identifier to cite or link to this item: http://hdl.handle.net/2440/79638
Citations
Scopus Web of Science® Altmetric
?
?
Full metadata record
DC FieldValueLanguage
dc.contributor.authorLee, P.en
dc.contributor.authorDuan, H.en
dc.contributor.authorVitkovsky, J.en
dc.contributor.authorZecchin, A.en
dc.contributor.authorGhidaoui, M.en
dc.date.issued2013en
dc.identifier.citationJournal of Hydraulic Research, 2013; 51(3):273-283en
dc.identifier.issn0022-1686en
dc.identifier.issn1814-2079en
dc.identifier.urihttp://hdl.handle.net/2440/79638-
dc.description.abstractThe operation of the transmission line models requires an input signal in the frequency domain describing the nature of the transient disturbance (for example, a valve closure) and an exact solution of the linearized mass and momentum equations for unsteady pipe flow. The use of the transmission line models does not require a strict adherence to a time–space discretization grid governed by the Courant condition, but it does require that the input signal be discretized in the frequency domain. This paper investigates the errors induced by the discretization of the input signal and provides guidelines for the appropriate selection of discretization size for the linear transmission line models. The accuracy of the model is quantified through comparison with a finely discretisated method of characteristics (MOC) model. The results show that the transmission line models are sensitive to the time–frequency discretization size and unlike the MOC, the appropriate size of the discretization changes depending on the transient event being modelled as well as the energy losses in the system.en
dc.description.statementofresponsibilityPedro J. Lee, Huan-Feng Duan, John P. Vítkovský, Aaron Zecchin and Mohamed Ghidaouien
dc.language.isoenen
dc.publisherInt Assn Hydraulic Researchen
dc.rights© 2013 International Association for Hydro-Environment Engineering and Researchen
dc.subjectClosed conduit; frequency domain; one-dimensional model; time domain; transient; water pipelineen
dc.titleThe effect of time-frequency discretization on the accuracy of the transmission line modelling of fluid transientsen
dc.typeJournal articleen
dc.identifier.rmid0020130416en
dc.identifier.doi10.1080/00221686.2012.749430en
dc.identifier.pubid18847-
pubs.library.collectionCivil and Environmental Engineering publicationsen
pubs.verification-statusVerifieden
pubs.publication-statusPublisheden
dc.identifier.orcidZecchin, A. [0000-0001-8908-7023]en
Appears in Collections:Civil and Environmental Engineering publications
Environment Institute publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.