Please use this identifier to cite or link to this item: http://hdl.handle.net/2440/80365
Citations
Scopus Web of Science® Altmetric
?
?
Type: Journal article
Title: Speckle-tracking strain of the left atrium: a transoesophageal echocardiographic validation study
Author: Leong, D.
Penhall, A.
Perry, R.
Shirazi, M.
Altman, M.
Chong, D.
Bradley, J.
Joseph, M.
Selvanayagam, J.
Citation: European Heart Journal Cardiovascular Imaging, 2013; 14(9):898-905
Publisher: Oxford University Press
Issue Date: 2013
ISSN: 2047-2404
2047-2412
Statement of
Responsibility: 
Darryl P. Leong, Amy Penhall, Rebecca Perry, Mitra Shirazi, Mikhail Altman, David Chong, Julie Bradley, Majo X. Joseph, and Joseph B. Selvanayagam
Abstract: <h4>Aims</h4>The aims of this study were (1) to evaluate the relationship between novel two-dimensional transthoracic indices of left atrial (LA) mechanical function (speckle-tracking- and tissue Doppler-derived parameters), conventional indices (A-wave peak velocity and velocity-time integral, and A' velocity), and transoesophageal echocardiographic parameters (LA appendage emptying velocity and spontaneous echocardiographic contrast); and (2) to assess to clinical feasibility of these novel transthoracic echocardiographic indices.<h4>Methods and results</h4>Transthoracic echocardiography was performed immediately prior to or following clinically indicated transoesophageal echocardiography in 100 individuals. Longitudinal reservoir LA strain, and reservoir, conduit, and atrial contractile strain rate were measured by both speckle-tracking and tissue Doppler approaches. Inter- and intra-observer variability in 20 randomly selected cases was evaluated by the Bland-Altman technique. The time required per analysis for these novel transthoracic echocardiographic indices was recorded. In relation to LA appendage emptying velocity, the respective absolute r-values for speckle-tracking reservoir strain, and reservoir, conduit, and atrial contractile strain rate were 0.53 (P < 0.001), 0.40 (P < 0.001), 0.21 (P = 0.05), and 0.61 (P < 0.001). The absolute r-values for tissue Doppler reservoir strain, and reservoir, conduit, and atrial contractile strain rate were 0.57 (P < 0.005), 0.53 (P < 0.001), 0.022 (P = 0.8), and 0.46 (P < 0.001), respectively. In contrast, the r-values for A-wave peak velocity and velocity-time integral, and A' velocity were 0.20 (P = 0.01), 0.26 (P = 0.05), and 0.35 (P = 0.007), respectively. Speckle-tracking-derived parameters achieved the greatest area-under-the-receiver-operating characteristic curve in the identification of moderate-severe LA spontaneous echocardigraphic contrast and were more rapidly measured (P < 0.001), while exhibiting similar reproducibility to tissue Doppler-derived measures.<h4>Conclusion</h4>Assessment of LA mechanical function using speckle-tracking echocardiography is a valid approach compared with transoesophageal echocardiography, and is clinically feasible.
Keywords: Left atrial function; Left atrial strain; Left atrial strain rate
Rights: © The Author 2013.
RMID: 0020131418
DOI: 10.1093/ehjci/jes323
Appears in Collections:Medicine publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.