Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/81499
Citations
Scopus Web of Science® Altmetric
?
?
Full metadata record
DC FieldValueLanguage
dc.contributor.authorRichardson, J.-
dc.contributor.authorBertaso, A.-
dc.contributor.authorFrost, L.-
dc.contributor.authorPsaltis, P.-
dc.contributor.authorCarbone, A.-
dc.contributor.authorKoschade, B.-
dc.contributor.authorWong, D.-
dc.contributor.authorNelson, A.-
dc.contributor.authorPaton, S.-
dc.contributor.authorWilliamson, K.-
dc.contributor.authorMohd Shah, A.-
dc.contributor.authorWorthley, M.-
dc.contributor.authorTeo, K.-
dc.contributor.authorGronthos, S.-
dc.contributor.authorZannettino, A.-
dc.contributor.authorWorthley, S.-
dc.date.issued2013-
dc.identifier.citationLaboratory Animals, 2013; 47(4):291-300-
dc.identifier.issn0023-6772-
dc.identifier.issn1758-1117-
dc.identifier.urihttp://hdl.handle.net/2440/81499-
dc.description.abstractIn vivo assessment of ventricular function in rodents has largely been restricted to transthoracic echocardiography (TTE). However 1.5 T cardiac magnetic resonance (CMR) and transoesophageal echocardiography (TOE) have emerged as possible alternatives. Yet, to date, no study has systematically assessed these three imaging modalities in determining ejection fraction (EF) in rats. Twenty rats underwent imaging four weeks after surgically-induced myocardial infarction. CMR was performed on a 1.5 T scanner, TTE was conducted using a 9.2 MHz transducer and TOE was performed with a 10 MHz intracardiac echo catheter. Correlation between the three techniques for EF determination and analysis reproducibility was assessed. Moderate-strong correlation was observed between the three modalities; the greatest between CMR and TOE (intraclass correlation coefficient (ICC) = 0.89), followed by TOE and TTE (ICC = 0.70) and CMR and TTE (ICC = 0.63). Intra- and inter-observer variations were excellent with CMR (ICC = 0.99 and 0.98 respectively), very good with TTE (0.90 and 0.89) and TOE (0.87 and 0.84). Each modality is a viable option for evaluating ventricular function in rats, however the high image quality and excellent reproducibility of CMR offers distinct advantages even at 1.5 T with conventional coils and software.-
dc.description.statementofresponsibilityJD Richardson, AG Bertaso, L Frost, PJ Psaltis, A Carbone, B Koschade, DT Wong, AJ Nelson, S Paton, K Williams, S Azarisman, MI Worthley, KS Teo, S Gronthos, ACW Zannettino and SG Worthley-
dc.language.isoen-
dc.publisherRoyal Soc Medicine Press Ltd-
dc.rights© The Author(s) 2013-
dc.source.urihttp://dx.doi.org/10.1177/0023677213494373-
dc.subjectcardiac magnetic resonance-
dc.subjecttransthoracic echocardiography-
dc.subjecttransoesophageal echocardiography-
dc.subjectleft ventricular function-
dc.subjectintracardiac echocardiography-
dc.titleCardiac magnetic resonance, transthoracic and transoesophageal echocardiography: a comparison of invivo assessment of ventricular function in rats-
dc.typeJournal article-
dc.identifier.doi10.1177/0023677213494373-
pubs.publication-statusPublished-
dc.identifier.orcidPsaltis, P. [0000-0003-0222-5468]-
dc.identifier.orcidNelson, A. [0000-0003-0990-2548]-
dc.identifier.orcidPaton, S. [0000-0001-7031-3510]-
dc.identifier.orcidGronthos, S. [0000-0002-6225-3084]-
dc.identifier.orcidZannettino, A. [0000-0002-6646-6167]-
Appears in Collections:Aurora harvest 4
Medicine publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.