Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/83631
Citations
Scopus Web of Science® Altmetric
?
?
Type: Journal article
Title: Quantitative Föster resonance energy transfer efficiency measurements using simultaneous spectral unmixing of excitation and emission spectra
Other Titles: Quantitative Foster resonance energy transfer efficiency measurements using simultaneous spectral unmixing of excitation and emission spectra
Author: Mustafa, S.
Hannagan, J.
Rigby, P.
Pfleger, K.
Corry, B.
Citation: Journal of Biomedical Optics, 2013; 18(2):026024-1-026024-14
Publisher: SPIE-Int Society Optical Engineering
Issue Date: 2013
ISSN: 1083-3668
1560-2281
Statement of
Responsibility: 
Sanam Mustafa, John Hannagan, Paul Rigby, Kevin Pfleger, and Ben Corry
Abstract: Accurate quantification of Förster resonance energy transfer (FRET) using intensity-based methods is difficult due to the overlap of fluorophore excitation and emission spectra. Consequently, mechanisms are required to remove bleedthrough of the donor emission into the acceptor channel and direct excitation of the acceptor when aiming to excite only the donor fluorophores. Methods to circumvent donor bleedthrough using the unmixing of emission spectra have been reported, but these require additional corrections to account for direct excitation of the acceptor. Here we present an alternative method for robust quantification of FRET efficiencies based upon the simultaneous spectral unmixing of both excitation and emission spectra. This has the benefit over existing methodologies in circumventing the issue of donor bleedthrough and acceptor cross excitation without the need for additional corrections. Furthermore, we show that it is applicable with as few as two excitation wavelengths and so can be used for quantifying FRET efficiency in microscope images as easily as for data collected on a spectrofluorometer. We demonstrate the accuracy of the approach by reproducing efficiency values in well characterized FRET standards: HEK cells expressing a variety of linked cerulean and venus fluorescent proteins. Finally we describe simple ImageJ plugins that can be used to calculate and create images of FRET efficiencies from microscope images.
Keywords: resonance energy transfer
ImageJ
FRET efficiency
fluorescent protein
spectral unmixing
confocal
spectral imaging
spectral bleedthrough
Rights: © The Authors. Published by SPIE under a Creative Commons Attribution 3.0 Unported License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI. [DOI: 10.1117/1.JBO.18.2.026024]
DOI: 10.1117/1.JBO.18.2.026024
Grant ID: http://purl.org/au-research/grants/arc/FT100100271
http://purl.org/au-research/grants/arc/FT100100271
Published version: http://dx.doi.org/10.1117/1.jbo.18.2.026024
Appears in Collections:Aurora harvest
Medical Sciences publications

Files in This Item:
File Description SizeFormat 
hdl_83631.pdfPublished version6.05 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.