Please use this identifier to cite or link to this item: http://hdl.handle.net/2440/8570
Citations
Scopus Web of Science® Altmetric
?
?
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSun, W.en
dc.contributor.authorSmout, A.en
dc.contributor.authorMalbert, C.en
dc.contributor.authorEdelbroek, M.en
dc.contributor.authorJones, K.en
dc.contributor.authorDent, J.en
dc.contributor.authorHorowitz, M.en
dc.date.issued1995en
dc.identifier.citationAmerican Journal of Physiology. Gastrointestinal and Liver Physiology, 1995; 268(3):G424-G430en
dc.identifier.issn0002-9513en
dc.identifier.issn2163-5773en
dc.identifier.urihttp://hdl.handle.net/2440/8570-
dc.description.abstractThe cutaneous electrogastrogram (EGG) and intraluminal antropyloroduodenal pressures were recorded in 12 healthy volunteers for 30-min periods during phase II of the interdigestive motor complex, during intraduodenal infusion of 10% triglyceride, and after intravenous erythromycin (3 mg/kg). During phase II, the frequency of the EGG was relatively constant in each individual, with a median frequency of 0.046 Hz [2.8 counts per minute (cpm)]. EGG frequency was greater (P < 0.05) than the median rate of antral pressure waves (1.8 cpm). The suppression of antral pressure waves (P < 0.05) and stimulation of isolated pyloric pressure waves (IPPWs) (P < 0.05) produced by triglyceride infusion were not associated with changes in EGG frequency compared with phase II. The frequency of the EGG and the rate of IPPWs were comparable. After erythromycin, EGG frequency was 0.03 Hz (1.8 cpm), less than during both phase II and triglyceride infusion (P < 0.05) and almost identical to the rate of antral pressure waves. Pressure waves were nearly always associated with an EGG signal. In contrast, the temporal relationship between the EGG signal and pressure waves was variable. During triglyceride infusion (r = 0.83, P < 0.001) and after erythromycin (r = 0.83, P < 0.001) there was a close (approximately 1:1) relationship between the rate of pressure waves and EGG frequency. However, there was no significant relationship (r = 0.32, not significant) between the number of pressure waves and EGG frequency frequency during pase II.en
dc.description.statementofresponsibilityW. M. Sun, A. Smout, C. Malbert, M. A. Edelbroek, K. Jones, J. Dent, and M. Horowitzen
dc.language.isoenen
dc.publisherAmerican Physiological Societyen
dc.rightsCopyright © 1995 the American Physiological Societyen
dc.source.urihttp://ajpgi.physiology.org/content/268/3/G424en
dc.subjectPyloric Antrum; Pylorus; Humans; Erythromycin; Triglycerides; Electrodiagnosis; Infusions, Intravenous; Manometry; Electrodes; Pressure; Adolescent; Adult; Female; Maleen
dc.titleRelationship between surface electrogastrography and antropyloric pressuresen
dc.typeJournal articleen
dc.identifier.rmid0030005138en
dc.identifier.doi10.1152/ajpgi.1995.268.3.g424en
dc.identifier.pubid69144-
pubs.library.collectionMedicine publicationsen
pubs.verification-statusVerifieden
pubs.publication-statusPublisheden
dc.identifier.orcidMalbert, C. [0000-0002-0665-4545]en
dc.identifier.orcidJones, K. [0000-0002-1155-5816]en
dc.identifier.orcidHorowitz, M. [0000-0002-0942-0306]en
Appears in Collections:Medicine publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.