Type: Journal article
Title: Application of bioreactance for cardiac output assessment during exercise in healthy individuals
Author: Elliott, A.
Hull, J.H.
Nunan, D.
Jakovljevic, D.G.
Brodie, D.
Ansley, L.
Citation: European Journal of Applied Physiology, 2010; 109(5):945-951
Publisher: Springer-Verlag
Issue Date: 2010
ISSN: 1439-6319
1439-6327
Statement of
Responsibility: 
Adrian Elliott, James H. Hull, David Nunan, Djordje G. Jakovljevic, David Brodie, Lesley Ansley
Abstract: In patients with cardiac failure, bioreactance-based cardiac output (CO) monitoring provides a valid non-invasive method for assessing cardiac performance during exercise. The purpose of this study was to evaluate the efficacy of this technique during strenuous exercise in healthy, trained individuals. Fourteen recreational cyclists, mean (SD) age of 34 (8) years and relative peak oxygen uptake of (VO2) 56 (6) ml kg−1 min−1, underwent incremental maximal exercise testing, whilst CO was recorded continuously using a novel bioreactance-based device (CObio). The CObio was evaluated against relationship with VO2, theoretical calculation of arterial-venous oxygen difference (C(a − v) O2) and level of agreement with an inert gas rebreathing method (COrb) using a Bland–Altman plot. Bioreactance-based CO measurement was practical and straightforward in application, although there was intermittent loss of electrocardiograph signal at high-intensity exercise. At rest and during exercise, CObio was strongly correlated with VO2 (r = 0.84; P < 0.001), however, there was evidence of systematic bias with CObio providing lower values than COrb; mean bias (limits of agreement) −19% (14.6 to −53%). Likewise, calculated (C(a − v) O2) was greater when determined using CObio than COrb (P < 0.001), although both devices provided values in excess of those reported in invasive studies. Bioreactance-based determination of CO provides a pragmatic approach to the continuous assessment of cardiac performance during strenuous exercise in trained individuals. Our findings, however, suggest that further work is needed to refine the key measurement determinants of CO using this device to improve measurement accuracy in this setting.
Keywords: Rebreathing methods
Exercise testing
Oxygen uptake
Exercise hemodynamics
Rights: © Springer-Verlag 2010
DOI: 10.1007/s00421-010-1440-8
Published version: http://dx.doi.org/10.1007/s00421-010-1440-8
Appears in Collections:Aurora harvest 2
Physiology publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.