Please use this identifier to cite or link to this item: http://hdl.handle.net/2440/8795
Citations
Scopus Web of Science® Altmetric
?
?
Full metadata record
DC FieldValueLanguage
dc.contributor.authorWishart, J.en
dc.contributor.authorHorowitz, M.en
dc.contributor.authorMorris, H.en
dc.contributor.authorNeed, A.en
dc.contributor.authorRusso, A.en
dc.contributor.authorJones, K.en
dc.contributor.authorSun, W.en
dc.contributor.authorNordin, B.en
dc.date.issued1995en
dc.identifier.citationEuropean Journal of Clinical Investigation, 1995; 25(2):123-127en
dc.identifier.issn0014-2972en
dc.identifier.issn1365-2362en
dc.identifier.urihttp://hdl.handle.net/2440/8795-
dc.description.abstractThe relationship between calcium absorption and gastric emptying and the precision of measurement of fractional calcium absorption using a single isotope technique were evaluated in 14 normal postmenopausal women (age range 61–72 years). On two occasions separated by between 5 and 15 days, each subject was given 250 mL water containing 0.2 MBq of 45Ca in 20 mg of calcium carrier as the chloride, 20 mg kg-1 paracetamol and 9 MBq of 99mTc sulphur colloid. Venous blood samples were taken at -2, 15, 30, 45, 60, 90, 120, 150 and 180 min after consumption of the drink, and gastric emptying (GE) was monitored with a gamma camera. Fractional calcium absorption in the first hour (α6) was calculated from the blood samples obtained at 15, 30, 45, 60, 90 and 120 min. An absorption rate was also derived from the 60 min sample using only a calibration curve (α1). There were close correlations between radiocalcium absorption on the two study days (r= 0.89, P < 0.001 for both α1 and α6) and between α1 and α6 (r= 0.93, P < 0.001). Plasma paracetamol concentrations at 15 min were directly related to the early phase of GE (r= 0.42, P < 0.05). In contrast, calcium absorption was inversely related to GE (r— 0.45, P < 0.05). We conclude that radiocalcium absorption is not greatly influenced by gastric emptying rate and that the single blood sample procedure has similar precision to the six-blood sample test.en
dc.description.statementofresponsibilityJ. M. Wishart, M. Horowitz, H. A. Morris, A. G. Need, A. Russo, K. L. Jones, W. M. Sun And B. E. C. Nordinen
dc.language.isoenen
dc.publisherBlackwell Scientific Publ.en
dc.subjectCalcium absorption; gastric emptying; paracetamol; osteoporosisen
dc.titleRelationship between fractional calcium absorption and gastric emptyingen
dc.typeJournal articleen
dc.identifier.rmid0030004985en
dc.identifier.doi10.1111/j.1365-2362.1995.tb01536.xen
dc.identifier.pubid68991-
pubs.library.collectionMedicine publicationsen
pubs.verification-statusVerifieden
pubs.publication-statusPublisheden
dc.identifier.orcidHorowitz, M. [0000-0002-0942-0306]en
dc.identifier.orcidMorris, H. [0000-0002-2745-3750]en
dc.identifier.orcidJones, K. [0000-0002-1155-5816]en
Appears in Collections:Medicine publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.