Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/88500
Citations
Scopus Web of Science® Altmetric
?
?
Type: Journal article
Title: Chlamydia antibody testing and diagnosing tubal pathology in subfertile women: an individual patient data meta-analysis
Author: Broeze, K.
Opmeer, B.
Coppus, S.
Van Geloven, N.
Alves, M.
Anestad, G.
Bhattacharya, S.
Allan, J.
Guerra-Infante, M.
Den Hartog, J.
Land, J.
Idahl, A.
van der Linden, P.
Mouton, J.
Ng, E.
van der Steeg, J.
Steures, P.
Svenstrup, H.
Tiitinen, A.
Toye, B.
et al.
Citation: Human Reproduction Update, 2011; 17(3):301-310
Publisher: Oxford University Press
Issue Date: 2011
ISSN: 1355-4786
1460-2369
Statement of
Responsibility: 
K.A. Broeze ... B.W. Mol ... et al.
Abstract: BACKGROUND The Chlamydia IgG antibody test (CAT) shows considerable variations in reported estimates of test accuracy, partly because of the use of different assays and cut-off values. The aim of this study was to reassess the accuracy of CAT in diagnosing tubal pathology by individual patient data (IPD) meta-analysis for three different CAT assays. METHODS We approached authors of primary studies that used micro-immunofluorescence tests (MIF), immunofluorescence tests (IF) or enzyme-linked immunosorbent assay tests (ELISA). Using the obtained IPD, we performed pooled receiver operator characteristics analysis and logistic regression analysis with a random effects model to compare the three assays. Tubal pathology was defined as either any tubal obstruction or bilateral tubal obstruction. RESULTS We acquired data of 14 primary studies containing data of 6191 women, of which data of 3453 women were available for analysis. The areas under the curve for ELISA, IF and MIF were 0.64, 0.65 and 0.75, respectively (P-value < 0.001) for any tubal pathology and 0.66, 0.66 and 0.77, respectively (P-value = 0.01) for bilateral tubal pathology. CONCLUSIONS In Chlamydia antibody testing, MIF is superior in the assessment of tubal pathology. In the initial screen for tubal pathology MIF should therefore be the test of first choice.
Keywords: Humans
Chlamydia trachomatis
Chlamydia Infections
Fallopian Tube Diseases
Immunoglobulin G
Fluorescent Antibody Technique
Enzyme-Linked Immunosorbent Assay
Sensitivity and Specificity
Research Design
Female
Rights: © The Author 2011.
DOI: 10.1093/humupd/dmq060
Published version: http://dx.doi.org/10.1093/humupd/dmq060
Appears in Collections:Aurora harvest 7
Paediatrics publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.