Title: Dynamic phasor estimation in electrical power systems based on IEC61850 Process-Bus.
Author: Abdolkhalig, Ahmed
Issue Date: 2015
School/Discipline: School of Electrical and Electronic Engineering
Abstract: State estimators in electrical power systems are implemented based on measurements that are provided by the SCADA systems or more recently, by dynamic phasor measurement units. The shortages of traditional SCADA systems such as the asynchronicity, the lack of using measurements with high sampling rates and complexity make them ineffective in capturing the dynamic response of a power system. Enhancing the performance of the state estimation by adding more dedicated phasor measurement units is costly. For reducing the cost and complexity of delivering measurements, IEC 61850 part-9-2 has been proposed using technology of Ethernet network communication. It uses a Process-Bus to link the equipment at switchyard and devices of protection and control at bay level. To enhance the phasor estimation and move from static to dynamic estimation, the high sampling rate of raw data provided by the Merging Unit as defined in IEC 61850 part-9-2 in combination with a Unscented Kalman filter as a dynamic estimator is proposed in the thesis. The major technical challenge that arises in applying Ethernet network communication is the impact of traffic performance on the estimated phasors and hence the substation protection and control reliability. This thesis work is to study the performance of proposed dynamic phasor estimator influenced by delay and/or loss of the Sampled Measured Value time critical messages over the Ethernet network communication. Detailed modelling of the Sampled Measured Value packet format and the IEC 61850 based digital communication are carried out using C programming language and TrueTime simulation tool is presented. To benefit from the raw Sampled Measured Values streamed with high sampling rate from Merging Units at substation process level, Unscented Kalman Filter Model-Based for dynamic phasor estimation is developed and proposed to be used at substation bay level in this thesis. To show how some protective relays can react to the proposed dynamic phasor estimation model under the IEC 61850-9-2 communication, an overcurrent protective relay is implemented based on the proposed dynamic phasor estimation and tested against different operation conditions of the IEC 61850 Process-Bus.
Advisor: Zivanovic, Rastko
Al-Sarawi, Said Fares Khalil
Dissertation Note: Thesis (Ph.D.) -- University of Adelaide, School of Electrical and Electronic Engineering, 2015
Keywords: IEC 61850 Process-Bus; sampled measured values; Kalman filter; digital over-current relay
Provenance: This electronic version is made publicly available by the University of Adelaide in accordance with its open access policy for student theses. Copyright in this thesis remains with the author. This thesis may incorporate third party material which has been used by the author pursuant to Fair Dealing exceptions. If you are the owner of any included third party copyright material you wish to be removed from this electronic version, please complete the take down form located at: http://www.adelaide.edu.au/legals
Appears in Collections:Research Theses

Files in This Item:
File Description SizeFormat 
01front.pdf488.85 kBAdobe PDFView/Open
02whole.pdf2.69 MBAdobe PDFView/Open
Permissions
  Restricted Access
Library staff access only3.26 MBAdobe PDFView/Open
Restricted
  Restricted Access
Library staff access only2.69 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.