Please use this identifier to cite or link to this item: http://hdl.handle.net/2440/9381
Citations
Scopus Web of Science® Altmetric
?
?
Full metadata record
DC FieldValueLanguage
dc.contributor.authorRitz, M.en
dc.contributor.authorFraser, R.en
dc.contributor.authorEdwards, N.en
dc.contributor.authorDi Matteo, A.en
dc.contributor.authorChapman, M.en
dc.contributor.authorButler, R.en
dc.contributor.authorCmielewski, P.en
dc.contributor.authorTournadre, J.en
dc.contributor.authorDavidson, G.en
dc.contributor.authorDent, J.en
dc.date.issued2001en
dc.identifier.citationCritical Care Medicine, 2001; 29(9):1744-1749en
dc.identifier.issn0090-3493en
dc.identifier.issn1530-0293en
dc.identifier.urihttp://hdl.handle.net/2440/9381-
dc.description.abstract<h4>Objective</h4>To measure gastric emptying in ventilated critically ill patients with a new noninvasive breath test.<h4>Design</h4>Single-center, open study.<h4>Setting</h4>Combined medical and surgical intensive care unit of a university hospital.<h4>Subjects</h4>Thirty unselected mechanically ventilated critically ill patients receiving gastric feeding and 22 healthy volunteers.<h4>Interventions</h4>None.<h4>Patients</h4>After 4 hrs without feeding, intragastric infusion of 100 mL of a liquid meal (Ensure) labeled with 100 microL 13C-octanoic acid. End-expiratory breath samples were collected into evacuated tubes from the respirator circuit every 5 mins for the first hour, then every 15 mins for 3 hrs. End-expiratory breath samples were also collected from volunteers studied supine after an overnight fast following an identical infusion via a nasogastric tube. Breath 13CO2 was measured with an isotope ratio mass spectrometer.<h4>Measurements and main results</h4>Performance of the breath test posed no difficulty or interference with patient care. The CO2 level was >1% in 1297/1300 breath samples, indicating satisfactory end-expiratory timing. Data are median and interquartile range. Gastric emptying was slower in patients compared with volunteers: gastric emptying coefficient 2.93 (2.17-3.39) vs. 3.58 (3.18-3.79), p <.001 and gastric half emptying time, derived from the area under the 13CO2 curve, 155 min (130-220) vs. 133 min (120-145), p <.008. Fourteen of the 30 patients had a gastric emptying coefficient <95% of all volunteers and 11 had a gastric half emptying time longer than 95% of all volunteers. The Acute Physiology and Chronic Health Evaluation (APACHE II) score (median 22, range 13-43) either at admission or on the day of the study did not correlate with gastric emptying coefficient.<h4>Conclusion</h4>Gastric emptying of a calorie-dense liquid meal is slow in 40% to 45% of unselected mechanically ventilated patients in a combined medical and surgical intensive care unit. The 13C-octanoic acid breath test is a novel and useful bedside technique to measure gastric emptying in these patients.en
dc.description.statementofresponsibilityMarc A. Ritz, Rob Fraser, Nick Edwards, Addolorata C. Di Matteo, Marianne Chapman, Ross Butler, Patricia Cmielewski, Jean-Pierre Tournadre, Geoff Davidson and John Denten
dc.language.isoenen
dc.publisherLippincott Williams & Wilkinsen
dc.rights© 2001 by the Society of Critical Care Medicine and Lippincott Williams & Wilkinsen
dc.subjectmotility, stomach, gastric emptying, gastric stasis, enteral feeding, intensive care unit, critically ill, mechanical ventilation, breath test, techniqueen
dc.titleDelayed gastric emptying in ventilated critically ill patients: Measurement by 13C-octanoic acid breath testen
dc.typeJournal articleen
dc.identifier.rmid0020011061en
dc.identifier.doi10.1097/00003246-200109000-00015en
dc.identifier.pubid61606-
pubs.library.collectionMedicine publicationsen
pubs.verification-statusVerifieden
pubs.publication-statusPublisheden
dc.identifier.orcidChapman, M. [0000-0003-0710-3283]en
dc.identifier.orcidCmielewski, P. [0000-0002-2236-9410]en
Appears in Collections:Medicine publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.