Title: Effect of femoral head size on metal-on-HXLPE hip arthroplasty outcome in a combined analysis of six national and regional registries
Author: Allepuz, A.
Havelin, L.
Barber, T.
Sedrakyan, A.
Graves, S.
Bordini, B.
Hoeffel, D.
Cafri, G.
Paxton, E.
Citation: Journal of Bone and Joint Surgery, 2014; 96(Suppl. 1):12-18
Publisher: Journal of Bone and Joint Surgery
Issue Date: 2014
ISSN: 0021-9355
1535-1386
Statement of
Responsibility: 
Alex Allepuz, Leif Havelin, Thomas Barber, Art Sedrakyan, Stephen Graves, Barbara Bordini, Daniel Hoeffel, Guy Cafri and Elizabeth Paxton
Abstract: BACKGROUND: HXLPE (highly cross-linked polyethylene) has greater wear resistance compared with UHMWPE (ultra-high molecular weight polyethylene), which may contribute to improving the outcomes of total hip arthroplasty with a large femoral head. However, no information is available regarding the effect of femoral head size on the survivorship of HXLPE hip prostheses. The aim of the present study was to provide evidence regarding whether femoral head size has an effect on the risk of revision when an HXLPE liner is used on a metal head. METHODS: A distributed health data network was developed by the ICOR (International Consortium of Orthopaedic Registries). Six national and regional registries are participating in this network: Kaiser Permanente, HealthEast, the Emilia-Romagna region in Italy, the Catalan region in Spain, Norway, and Australia. Data from each registry were standardized and provided at an aggregate level for each of the variables of interest. Patients with osteoarthritis who were forty-five to sixty-four years of age and had undergone uncemented total hip arthroplasty were included in the present study. Analyses were performed on the basis of individual patient profiles, utilizing the variables collected from each registry. The outcome of interest was the time to the first revision (for any reason). Survival probabilities and their standard errors were extracted from each registry for each unique combination of the covariates and were combined through multivariate meta-analysis utilizing linear mixed models to compare survivorship for <32-mm, 32-mm, and >32-mm femoral head sizes. RESULTS: A total of 14,372 total hip arthroplasties were included in the study. The five-year rate of revision surgery varied from 1.9% to 3.2% among registries. The risk of revision did not differ significantly between <32-mm and 32-mm head sizes (HR [hazard ratio] = 0.91, 95% CI [confidence interval] = 0.69 to 1.19) or between >32-mm and 32-mm sizes (HR = 1.05, 95% CI = 0.70 to 1.55). CONCLUSIONS: The results of our study provide relevant data to orthopaedic surgeons deciding on the use of a larger articulation in a metal-on-polyethylene bearing. A larger head diameter should not be considered a detriment to device survival when an HXLPE liner is used. However, efforts to force the use of a large-size implant appear unsupported, as similar survivorship was observed for all head diameter groups.
Keywords: Osteoarthritis, Hip; Hip Dislocation; Prosthesis Failure; Arthroplasty, Replacement, Hip; Prosthesis Design; Hip Prosthesis