Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/99088
Citations
Scopus Web of Science® Altmetric
?
?
Type: Journal article
Title: Detection of gold nanoparticles with different sizes using absorption and fluorescence based method
Author: Zuber, A.
Purdey, M.
Schartner, E.
Forbes, C.
Van Der Hoek, B.
Giles, D.
Abell, A.
Monro, T.
Ebendorff-Heidepriem, H.
Citation: Sensors and Actuators B: Chemical: international journal devoted to research and development of physical and chemical transducers, 2016; 227:117-127
Publisher: Elsevier
Issue Date: 2016
ISSN: 0925-4005
Statement of
Responsibility: 
Agnieszka Zuber, Malcolm Purdey, Erik Schartner, Caroline Forbes, Benjamin van der Hoek, David Giles, Andrew Abell, Tanya Monro, Heike Ebendorff-Heidepriem
Abstract: Growing world demand for gold and decreasing discovery rates of ore deposits necessitates new tech-niques for gold exploration. Current techniques for the detection of ppb level of gold, such as inductivelycoupled plasma mass spectrometry (ICP-MS) are not field-deployable. By contrast, current portable devicesuch as X-ray fluorescence (XRF) based sensors are not sufficiently sensitive. Thus, there is growing inter-est in developing a new, easy-to-use and fast method for detection of low concentrations of gold at thesite of an exploration drilling rig.Two optical methods, absorption and fluorescence, are examined for their suitability for low goldconcentration detection. Absorption study is based on the analysis of localised surface plasmon resonancepeak. For fluorescence analysis, the ability of gold nanoparticles to specifically catalyse the conversionof the non-fluorescent compound (I-BODIPY) to the fluorescent derivative (H-BODIPY) is used. For bothabsorption and fluorescence methods, the limit of quantification (LOQ) of gold nanoparticles (NPs) wasfound to be dependent on the NP size (71 ppb of 5 nm and 24.5 ppb of 50 nm NPs for absorption and 74 ppbof 5 nm and 1200 ppb of 50 nm NPs for fluorescence). The LOQ for fluorescence for 50 nm NPs measuredin a suspended core optical fibre was almost twice lower than in a cuvette. The field deployment potentialof these methods was also determined using a portable set up.
Rights: © 2015 The Authors. Published by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
DOI: 10.1016/j.snb.2015.12.044
Published version: http://dx.doi.org/10.1016/j.snb.2015.12.044
Appears in Collections:Aurora harvest 7
Medicine publications

Files in This Item:
File Description SizeFormat 
hdl_99088.pdfPublished version2.86 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.