2-year outcomes after stenting of lipid-rich and nonrich coronary plaques

Date

2020

Authors

Yamamoto, M.H.
Maehara, A.
Stone, G.W.
Kini, A.S.
Brilakis, E.S.
Rizik, D.G.
Shunk, K.
Powers, E.R.
Tobis, J.M.
Maini, B.S.

Editors

Advisors

Journal Title

Journal ISSN

Volume Title

Type:

Journal article

Citation

Journal of the American College of Cardiology, 2020; 75(12):1371-1382

Statement of Responsibility

Myong HwaYamamoto, Akiko Maehara, Gregg W.Stone, Annapoorna S.Kini, Emmanouil S.Brilakis ... Stephen Nicholls

Conference Name

Abstract

Background: Autopsy studies suggest that implanting stents in lipid-rich plaque (LRP) may be associated with adverse outcomes. Objectives: The purpose of this study was to evaluate the association between LRP detected by near-infrared spectroscopy (NIRS) and clinical outcomes in patients with coronary artery disease treated with contemporary drug-eluting stents. Methods: In this prospective, multicenter registry, NIRS was performed in patients undergoing coronary angiography and possible percutaneous coronary intervention (PCI). Lipid core burden index (LCBI) was calculated as the fraction of pixels with the probability of LRP >0.6 within a region of interest. MaxLCBI4mm was defined as the maximum LCBI within any 4-mm-long segment. Major adverse cardiac events (MACE) included cardiac death, myocardial infarction, definite or probable stent thrombosis, or unplanned revascularization or rehospitalization for progressive angina or unstable angina. Events were subcategorized as culprit (treated) lesion–related, nonculprit (untreated) lesion–related, or indeterminate. Results: Among 1,999 patients who were enrolled in the COLOR (Chemometric Observations of Lipid Core Plaques of Interest in Native Coronary Arteries Registry), PCI was performed in 1,621 patients and MACE occurred in 18.0% of patients, of which 8.3% were culprit lesion–related, 10.7% were nonculprit lesion–related, and 3.1% were indeterminate during 2-year follow-up. Complications from NIRS imaging occurred in 9 patients (0.45%), which resulted in 1 peri-procedural myocardial infarction and 1 emergent coronary bypass. Pre-PCI NIRS imaging was obtained in 1,189 patients, and the 2-year rate of culprit lesion–related MACE was not significantly associated with maxLCBI4mm (hazard ratio of maxLCBI4mm per 100: 1.06; 95% confidence interval: 0.96 to 1.17; p = 0.28) after adjusting clinical and procedural factors. Conclusions: Following PCI with contemporary drug-eluting stents, stent implantation in NIRS-defined LRPs was not associated with increased periprocedural or late adverse outcomes compared with those without significant lipid.

School/Discipline

Dissertation Note

Provenance

Description

Access Status

Rights

© 2020 by the American College of Cardiology Foundation. Published by Elsevier.

License

Grant ID

Call number

Persistent link to this record