Chen, E.Wu, X.Zhao, Y.Hu, E.Torres, J.F.2023-12-202023-12-202019Results in Engineering, 2019; 4:100066-1-100066-32590-12302590-1230https://hdl.handle.net/2440/140264On the basis of a validated model, a parametric study is conducted to understand the effects of operating parameters on the coefficient of performance (COP) and specific cooling power (SCP) of a stand-alone adsorption refrigeration tube (ART). It is revealed that the SCP obtained based on the model with the transient pressure process (TPP) boundary condition is approximately 20% higher than that obtained without the TPP. A scaling up solution of using multiple ARTs to produce continuous cooling is also proposed and discussed.en© 2019 Published by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).coefficient of performance (COP)specific cooling power (SCP)Scaling up capacity of stand-alone adsorption refrigeration tubesJournal article10.1016/j.rineng.2019.1000662023-12-20513057Hu, E. [0000-0002-7390-0961]