dc.description.abstractTherapeutic drug monitoring (TDM) of cyclosporine (CsA) has been an accepted as an essential tool in the management of solid organ transplant recipients. The authors evaluated a new CsA method, Immunotech cyclosporine direct radioimmunoassay (Beckman Coulter, Prague, Czech Republic), for the measurement of whole-blood CsA concentrations. The performance was compared with CEDIA Plus method as well as group mean data for HPLC and other immunoassays available from the International CsA Proficiency Testing Program (www.bioanalytics.co.uk). Regression analysis of patient samples gave a relationship of RIA = 1.0822 CEDIA(+) + 69.84 (r(2) = 0.933). External CsA-spiked proficiency-testing (PT) samples gave a regression equation of RIA = 0.9672 CEDIA(+) + 4.99 (r(2) = 0.996). The correlation with the CEDIA Plus method using patient specimens (hence, including CsA metabolites) suggested that the test RIA method possibly had slightly inferior specificity for parent CsA. The results suggest that the Immunotech cyclosporine direct RIA kit is suitable for the measurement of whole-blood CsA concentrations and maintained clinically acceptable analytic precision and accuracy, displaying CVs of less than 15% and biases of less than 10%. The PT program CsA-metabolite-free samples showed that calibration between methods was comparable with the possible exception of mFPIA/TDx.-
dc.language.isoen-
dc.publisherLippincott Williams & Wilkins-
dc.source.urihttp://dx.doi.org/10.1097/00007691-200502000-00016-
dc.subjectHumans-
dc.subjectIodine Radioisotopes-
dc.subjectCyclosporine-
dc.subjectRadioimmunoassay-
dc.subjectDrug Monitoring-
dc.subjectImmunoenzyme Techniques-
dc.subjectKidney Transplantation-
dc.subjectReproducibility of Results-
dc.titleEvaluation of the immunotech cyclosporine direct radioimmunoassay for the determination of whole-blood cyclosporine in renal transplant patients-
dc.typeJournal article-
dc.identifier.doi10.1097/00007691-200502000-00016-
pubs.publication-statusPublished-
dc.identifier.orcidSallustio, B. [0000-0002-0186-3073]-
Appears in Collections:Aurora harvest 6
Pharmacology publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.