Please use this identifier to cite or link to this item:
https://hdl.handle.net/2440/22772
Citations | ||
Scopus | Web of Science® | Altmetric |
---|---|---|
?
|
?
|
Type: | Journal article |
Title: | Enantioselective assay for the determination of perhexiline enantiomers in human plasma by liquid chromatography |
Author: | Davies, B. Herbert, M. Culbert, J. Pyke, S. Coller, J. Somogyi, A. Milne, R. Sallustio, B. |
Citation: | Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences, 2006; 832(1):114-120 |
Publisher: | Elsevier Science BV |
Issue Date: | 2006 |
ISSN: | 1570-0232 1873-376X |
Statement of Responsibility: | Benjamin J. Davies, Megan K. Herbert, Julie A. Culbert, Simon M. Pyke, Janet K. Coller, Andrew A. Somogyi, Robert W. Milne and Benedetta C. Sallustio |
Abstract: | Effective use of the antianginal agent perhexiline is difficult because saturable metabolism by the polymorphic cytochrome P450 2D6 (CYP2D6) isoform produces elevated plasma perhexiline concentrations that have been associated with serious hepatic and neurological toxicity. Perhexiline is marketed for therapeutic use as a racemate and there is evidence for differences in the disposition of its enantiomers. The current study describes an enantioselective HPLC-fluorescent method utilising pre-column derivatization with (R)-(−)-1-(1-napthyl)ethyl isocyanate. Following derivatization, the enantiomers are resolved on a C18 column with gradient elution using a mobile phase composed of methanol and water. The method described is suitable for the quantification of (+)- and (−)-perhexiline in human plasma following clinical doses and demonstrates sufficient sensitivity, accuracy and precision between 0.01 and 2.00 mg/l for each enantiomer, with intra-assay coefficients of variation and bias <20% at 0.01 mg/l and <10% at 2.00 mg/l, and inter-assay coefficients of variation and biases <15% at 0.03 mg/l and <10% at 0.40 and 0.75 mg/l. The application of this method to plasma samples collected from a patient treated with perhexiline revealed that (+)-perhexiline concentrations were higher than (−)-perhexiline concentrations, confirming the stereoselective disposition of perhexiline. The current study describes an enantioselective method that utilises pre-column formation of fluorescent diastereomers that are resolved on a C18 HPLC column using a gradient of methanol and water. |
Keywords: | Enantiomer separation HPLC perhexiline |
Description: | Copyright © Elsevier B.V. All rights reserved. |
DOI: | 10.1016/j.jchromb.2005.12.046 |
Description (link): | http://www.elsevier.com/wps/find/journaldescription.cws_home/643040/description#description |
Published version: | http://dx.doi.org/10.1016/j.jchromb.2005.12.046 |
Appears in Collections: | Aurora harvest 2 Pharmacology publications |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.