Title: The efficacy of hemostatic techniques in the sheep model of carotid artery injury
Author: Valentine, R.
Boase, S.
Jervis-Bardy, J.
Dones Cabral, J.
Robinson, S.
Wormald, P.
Citation: International Forum of Allergy and Rhinology, 2011; 1(2):118-122
Publisher: American Rhinologic Society
Issue Date: 2011
ISSN: 2042-6976
2042-6984
Statement of
Responsibility: 
Rowan Valentine, Sam Boase, Josh Jervis-Bardy, Jay-Dee Dones Cabral, Simon Robinson, Peter-John Wormald
Abstract: <h4>Background</h4>The most dramatic complication in endonasal surgery is inadvertent injury to the internal carotid artery (ICA) with massive bleeding. Nasal packing is the favored technique for control; however, this often causes complete carotid occlusion or carotid stenosis, contributing to the morbidity and mortality of the patient. The aim of this study is to compare the efficacy of endoscopically applied hemostatic techniques that maintain vascular flow in an animal model of carotid artery injury.<h4>Methods</h4>A total of 20 sheep underwent ICA dissection/isolation followed by the placement of the artery within a modified "sinus model otorhino neuro trainer" (SIMONT) model. A standardized 4-mm carotid artery injury was created endoscopically. Randomization of sheep to receive 1 of 5 hemostatic techniques was performed (Floseal, oxidized regenerated cellulose, Chitosan gel, muscle patch, or the U-Clip anastomotic device). Specific outcome measures were time to hemostasis, duration of time mean arterial pressure (MAP) was >55 mmHg, blood loss, and survival time.<h4>Results</h4>Muscle patch hemostasis and the U-Clip anastomotic device were significantly more effective at achieving primary hemostasis rapidly, reducing total blood loss, and increasing survival time and time MAP was >55 mmHg more than Floseal, oxidized regenerated cellulose, and Chitosan gel (p < 0.05). Additionally, all muscle patch-treated and U-Clip device-treated sheep achieved primary hemostasis and reached the endpoint of observation, while maintaining vascular patency. Floseal and oxidized regenerated cellulose failed to achieve hemostasis in any animal, with all animals exsanguinating prematurely.<h4>Conclusion</h4>In the sheep model of endoscopic ICA injury, the muscle patch and U-Clip anastomotic device significantly improved survival, reduced blood loss, and achieved primary hemostasis while maintaining vascular patency.
Keywords: carotid
endonasal surgery
hemostasis
packing
skull base
Rights: Copyright © 2011 American Rhinologic Society-American Academy of Otolaryngic Allergy, LLC
DOI: 10.1002/alr.20033
Published version: http://dx.doi.org/10.1002/alr.20033
Appears in Collections:Aurora harvest 5
Surgery publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.