Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/71421
Full metadata record
DC FieldValueLanguage
dc.contributor.authorBockler, D.-
dc.contributor.authorRiambau, V.-
dc.contributor.authorFitridge, R.-
dc.contributor.authorWolf, Y.-
dc.contributor.authorHayes, P.-
dc.contributor.authorSilveira, P.-
dc.contributor.authorNuman, F.-
dc.date.issued2011-
dc.identifier.citationThe Journal of Cardiovascular Surgery: a journal on cardiac, vascular and thoracic surgery, 2011; 52(5):669-681-
dc.identifier.issn0021-9509-
dc.identifier.issn1827-191X-
dc.identifier.urihttp://hdl.handle.net/2440/71421-
dc.description.abstractThe Endurant Stent-graft System (Medtronic Vascular, Santa Rosa, CA) is a next-generation device intended to expand the applicability of endovascular aortic repair (EVAR). To date, the Endurant has been evaluated in 9 short- and intermediate-term studies, several in patients presenting with challenging aneurysm anatomies. Consistently, the device in these studies has been shown to be safe and effective, with an excellent rate of deployment success and with very low rates of type I/III endoleaks and reinterventions. Single center experience with Endurant in challenging anatomies with short kinked necks and calcified angulated iliac arteries in patients unfit for open repair and challenging anatomies show promising early results with no difference in mortality, morbidity and reintervention rates, but need cautious application for EVAR outside of the device-specific IFU. The Endurant Stent-graft Natural Selection Global Postmarket Registry (ENGAGE) is a long-term 1266-patient 80-site worldwide prospective postmarket study initiated to augment the knowledge base (poolable and comparable) about EVAR in a real-world population implanted with the Endurant. Technical and clinical data for ENGAGE patients will be reported through the expected completion of 5-year follow-up for all ENGAGE registry patients in 2018. We discuss the evolving challenges for EVAR that the Endurant and other next-generation stent-grafts are designed to address and review outcomes published with the Endurant since the CE marking of the device in July 2008.-
dc.description.statementofresponsibilityD. Böckler, V. Riambau, R. Fitridge, Y. Wolf, P. Hayes, P.G. Silveira, F. Numan, for The Engage Investigators-
dc.language.isoen-
dc.publisherEdizioni Minerva Medica-
dc.rights© Edizioni Minerva Medica - Torino 2011-
dc.subjectAortic aneurysms, abdominal-
dc.subjectAnatomy complications-
dc.subjectRegistries-
dc.titleWorldwide experience with the Endurant Stent-graft System: Review of the literature-
dc.typeJournal article-
pubs.publication-statusPublished-
dc.identifier.orcidFitridge, R. [0000-0001-6258-5997]-
Appears in Collections:Aurora harvest
Surgery publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.