Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/83028
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGu, D.-
dc.contributor.authorSun, Z.-
dc.contributor.authorMedwell, P.-
dc.contributor.authorAlwahabi, Z.-
dc.contributor.authorNathan, G.-
dc.contributor.editorZhu, M.-
dc.contributor.editorMa, Y.-
dc.contributor.editorYu, Y.-
dc.contributor.editorVuthaluru, H.-
dc.contributor.editorZhang, Z.-
dc.contributor.editorZhang, D.-
dc.date.issued2013-
dc.identifier.citationProceedings of the Australian Combustion Symposium, Perth, WA, 6-8 November 2013 / Mingming Zhu, Yu Ma, Yun Yu, Hari Vuthaluru, Zhezi Zhang and Dongke Zhang (eds.): pp.263-266-
dc.identifier.urihttp://hdl.handle.net/2440/83028-
dc.description.abstractTwo-line Atomic Fluorescence (TLAF) using seeded atomic indium is a promising technique for two-dimensional temperature measurement in turbulent non-premixed sooty flames. However, it is desirable to reduce measurement uncertainties, which in turn depends on the fluorescence signal relative to background noise and interference. This paper reports a spectral assessment of interferences to both the Stokes and Anti-Stokes fluorescence signals in turbulent sooty flames undertaken with a spectrometer. Flame emission spectra were measured to assess the effects of various interference sources on indium fluorescence signals as well as to evaluate the efficacy of two techniques with potential to enhance the signal-to-noise ratio. Three types of interferences have been identified: laser Mie scattering from soot particles, laser-induced fluorescence from polycyclic aromatic hydrocarbons species (PAH-LIF) and laser-induced incandescence (LII) from soot particles. The feasibility of applying a correction for interferences by comparison of simultaneous images collected on- and off-resonance was assessed by collecting images at 430 nm and the fluorescence lines (410 and 450 nm). The correlation between the intensity of corresponding pixels from two instantaneous on- and off-resonance images was compared. This correction scheme was found to have limited value. The alternative scheme, which incorporates narrow-band filters, is considered to have much greater potential to be effective.-
dc.description.statementofresponsibilityD.H. Gu, Z.W. Sun, P.R. Medwell, Z.T. Alwahabi and G.J. Nathan-
dc.description.urihttp://cfe.uwa.edu.au/news/acs2013-
dc.description.urihttp://cfe.uwa.edu.au/news/acs2013-
dc.language.isoen-
dc.publisherThe Combustion Institute Australian & New Zealand Section-
dc.rights© the authors-
dc.source.urihttp://www.anz-combustioninstitute.org/local/papers/ACS2013-Conference-Proceedings.pdf-
dc.subjectCombustion-
dc.subjectlaser diagnostics-
dc.subject2D-temperature-
dc.subjectturbulent sooty flame-
dc.titleSpectral Assessment of Interferences to Two-line Atomic Fluorescence (TLAF) in Turbulent Sooty Flames-
dc.typeConference paper-
dc.contributor.conferenceAustralian Combustion Symposium (4th: 2013 : Perth, Western Australia)-
dc.publisher.placeAustralia-
pubs.publication-statusPublished-
dc.identifier.orcidSun, Z. [0000-0001-7899-9676]-
dc.identifier.orcidMedwell, P. [0000-0002-2216-3033]-
dc.identifier.orcidAlwahabi, Z. [0000-0003-4831-7798]-
dc.identifier.orcidNathan, G. [0000-0002-6922-848X]-
Appears in Collections:Aurora harvest 4
Mechanical Engineering conference papers

Files in This Item:
File Description SizeFormat 
hdl_83028.pdfPublished version698.46 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.