dc.description.abstractPeripheral photon and neutron doses from external beam radiotherapy (EBRT) are associated with increased risk of carcinogenesis in the out-of-field organs; thus, dose estimations of secondary radiation are imperative. Peripheral photon and neutron doses from EBRT of prostate carcinoma were measured in Rando phantom. (6)LiF:Mg,Cu,P and (7)LiF:Mg,Cu,P glass-rod thermoluminescence dosemeters (TLDs) were inserted in slices of a Rando phantom followed by exposure to 80 Gy with 18-MV photon four-field 3D-CRT technique. The TLDs were calibrated using 6- and 18-MV X-ray beam. Neutron dose equivalents measured with CR-39 etch-track detectors were used to derive readout-to-neutron dose conversion factor for (6)LiF:Mg,Cu,P TLDs. Average neutron dose equivalents per 1 Gy of isocentre dose were 3.8±0.9 mSv Gy(-1) for thyroid and 7.0±5.4 mSv Gy(-1) for colon. For photons, the average dose equivalents per 1 Gy of isocentre dose were 0.2±0.1 mSv Gy(-1) for thyroid and 8.1±9.7 mSv Gy(-1) for colon. Paired (6)LiF:Mg,Cu,P and (7)LiF:Mg,Cu,P TLDs can be used to measure photon and neutron doses simultaneously. Organs in close proximity to target received larger doses from photons than those from neutrons whereas distally located organs received higher neutron versus photon dose.-
dc.description.statementofresponsibilityEva Bezak, Rundgham Takam and Loredana G. Marcu-
dc.language.isoen-
dc.publisherOxford University Press (OUP)-
dc.rights© The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com-
dc.source.urihttp://dx.doi.org/10.1093/rpd/ncu362-
dc.subjectHumans-
dc.subjectProstatic Neoplasms-
dc.subjectRadiation Dosage-
dc.subjectThermoluminescent Dosimetry-
dc.subjectPhantoms, Imaging-
dc.subjectNeutrons-
dc.subjectPhotons-
dc.subjectParticle Accelerators-
dc.subjectMale-
dc.subjectOrgans at Risk-
dc.titlePeripheral photon and neutron doses from prostate cancer external beam irradiation-
dc.typeJournal article-
dc.identifier.doi10.1093/rpd/ncu362-
pubs.publication-statusPublished-
dc.identifier.orcidBezak, E. [0000-0002-1315-1735]-
Appears in Collections:Aurora harvest 2
Physics publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.