Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/99757
Citations
Scopus Web of Science® Altmetric
?
?
Full metadata record
DC FieldValueLanguage
dc.contributor.authorJervis-Bardy, J.-
dc.contributor.authorLeong, L.-
dc.contributor.authorMarri, S.-
dc.contributor.authorSmith, R.-
dc.contributor.authorChoo, J.-
dc.contributor.authorSmith-Vaughan, H.-
dc.contributor.authorNosworthy, E.-
dc.contributor.authorMorris, P.-
dc.contributor.authorO'Leary, S.-
dc.contributor.authorRogers, G.-
dc.contributor.authorMarsh, R.-
dc.date.issued2015-
dc.identifier.citationMicrobiome, 2015; 3(1):19-1-19-11-
dc.identifier.issn2049-2618-
dc.identifier.issn2049-2618-
dc.identifier.urihttp://hdl.handle.net/2440/99757-
dc.descriptionPublished: 5 May 2015-
dc.description.abstractBackground: The rapid expansion of 16S rRNA gene sequencing in challenging clinical contexts has resulted in a growing body of literature of variable quality. To a large extent, this is due to a failure to address spurious signal that is characteristic of samples with low levels of bacteria and high levels of non-bacterial DNA. We have developed a workflow based on the paired-end read Illumina MiSeq-based approach, which enables significant improvement in data quality, post-sequencing. We demonstrate the efficacy of this methodology through its application to paediatric upper-respiratory samples from several anatomical sites. Results: A workflow for processing sequence data was developed based on commonly available tools. Data generated from different sample types showed a marked variation in levels of non-bacterial signal and ‘contaminant’ bacterial reads. Significant differences in the ability of reference databases to accurately assign identity to operational taxonomic units (OTU) were observed. Three OTU-picking strategies were trialled as follows: de novo, open-reference and closed-reference, with open-reference performing substantially better. Relative abundance of OTUs identified as potential reagent contamination showed a strong inverse correlation with amplicon concentration allowing their objective removal. The removal of the spurious signal showed the greatest improvement in sample types typically containing low levels of bacteria and high levels of human DNA. A substantial impact of pre-filtering data and spurious signal removal was demonstrated by principal coordinate and co-occurrence analysis. For example, analysis of taxon co-occurrence in adenoid swab and middle ear fluid samples indicated that failure to remove the spurious signal resulted in the inclusion of six out of eleven bacterial genera that accounted for 80% of similarity between the sample types. Conclusions: The application of the presented workflow to a set of challenging clinical samples demonstrates its utility in removing the spurious signal from the dataset, allowing clinical insight to be derived from what would otherwise be highly misleading output. While other approaches could potentially achieve similar improvements, the methodology employed here represents an accessible means to exclude the signal from contamination and other artefacts.-
dc.description.statementofresponsibilityJake Jervis-Bardy, Lex E X Leong, Shashikanth Marri, Renee J Smith, Jocelyn M Choo, Heidi C Smith-Vaughan, Elizabeth Nosworthy, Peter S Morris, Stephen O'Leary, Geraint B Rogers and Robyn L Marsh-
dc.language.isoen-
dc.publisherBioMed Central-
dc.rights© 2015 Jervis-Bardy et al.; licensee BioMed Central. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.-
dc.source.urihttp://dx.doi.org/10.1186/s40168-015-0083-8-
dc.subject16S rRNA; Respiratory; MiSeq; Contamination; Pair-end reads; QIIME; Otitis media-
dc.titleDeriving accurate microbiota profiles from human samples with low bacterial content through post-sequencing processing of Illumina MiSeq data-
dc.typeJournal article-
dc.identifier.doi10.1186/s40168-015-0083-8-
dc.relation.granthttp://purl.org/au-research/grants/nhmrc/1007641-
pubs.publication-statusPublished-
Appears in Collections:Aurora harvest 7
Surgery publications

Files in This Item:
File Description SizeFormat 
hdl_99757.pdfPublished version2.13 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.