Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/114043
Citations
Scopus Web of Science® Altmetric
?
?
Type: Journal article
Title: Stability of complex fractionated atrial electrograms: a systematic review
Author: Lau, D.
Maesen, B.
Zeemering, S.
Verheule, S.
Crijns, H.
Schotten, U.
Citation: Journal of Cardiovascular Electrophysiology, 2012; 23(9):980-987
Publisher: Wiley
Issue Date: 2012
ISSN: 1045-3873
1540-8167
Statement of
Responsibility: 
Dennis H. Lau, Bart Maesen, Stef Zeemering, Sander Verheule, Harry J. Crijns and Ulrich Schotten
Abstract: Stability of CFAE. Introduction: The efficacy of complex fractionated atrial electrograms (CFAE) ablation as additional substrate modification in atrial fibrillation (AF) patients has been shown to be highly variable. Recently, the validity of sequential CFAE mapping has been challenged by concerns regarding temporal stability of CFAE. Existing studies on CFAE stability are small with very different CFAE definitions. Here, we undertook a systematic literature review to address these controversial findings. Methods and Results: A systematic search of the scientific literature was performed through to September 1, 2011. From a total of 162 manuscripts, 7 were identified to contain assessment of the temporal stability of CFAE in human AF. These studies included a total of 96 (80 persistent/16 paroxysmal AF) patients (79% male, mean 58 years old). Varying CFAE mapping techniques or definitions were utilized. CFAE stability averaged 81% between 2 high-density sequential fractionation maps over an average time interval of 19 minutes. However, CFAE stability only averaged at 75% from shorter term continuous recordings (mean 15 comparisons within 75 seconds). Although the variability in CFAE cycle length was small (12-15 ms), coefficients of variation in continuous electrical activity were high (up to 300%). The overall spatial distribution of CFAE was found to be stable. Nevertheless, sequential mapping may not capture all CFAE sites given their dynamic characteristics. Conclusion: CFAE are temporally variable in keeping with the diverse mechanisms underlying their existence. The dynamic nature of CFAE will continue to pose a challenge for electrophysiologists in search of critical sites requiring ablation to combat AF.
Keywords: Atrial fibrillation; catheter ablation; complex fractionated atrial electrograms; mapping; stability
Rights: © 2012 Wiley Periodicals, Inc.
DOI: 10.1111/j.1540-8167.2012.02335.x
Grant ID: NHMRC
Published version: http://dx.doi.org/10.1111/j.1540-8167.2012.02335.x
Appears in Collections:Aurora harvest 8
Medicine publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.