Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/52134
Citations
Scopus Web of ScienceĀ® Altmetric
?
?
Type: Journal article
Title: Real-time non-invasive detection of inhalable particulates delivered into live mouse airways
Author: Donnelley, M.
Morgan, K.
Fouras, A.
Skinner, W.
Uesugi, K.
Yagi, N.
Siu, K.
Parsons, D.
Citation: Journal of Synchrotron Radiation, 2009; 16(Part 4):553-561
Publisher: Munksgaard Int Publ Ltd
Issue Date: 2009
ISSN: 0909-0495
1600-5775
Statement of
Responsibility: 
M. Donnelley, K. S. Morgan, A. Fouras, W. Skinner, K. Uesugi, N. Yagi, K. K. W. Siu and D. W. Parsons
Abstract: Fine non-biological particles small enough to be suspended in the air are continually inhaled as we breathe. These particles deposit on airway surfaces where they are either cleared by airway defences or can remain and affect lung health. Pollutant particles from vehicles, building processes and mineral and industrial dusts have the potential to cause both immediate and delayed health problems. Because of their small size, it has not been possible to non-invasively examine how individual particles deposit on live airways, or to consider how they behave on the airway surface after deposition. In this study, synchrotron phase-contrast X-ray imaging (PCXI) has been utilized to detect and monitor individual particle deposition. The in vitro detectability of a range of potentially respirable particulates was first determined. Of the particulates tested, only asbestos, quarry dust, fibreglass and galena (lead sulfate) were visible in vitro. These particulates were then examined after delivery into the nasal airway of live anaesthetized mice; all were detectable in vivo but each exhibited different surface appearances and behaviour along the airway surface. The two fibrous particulates appeared as agglomerations enveloped by fluid, while the non-fibrous particulates were present as individual particles. Synchrotron PCXI provides the unique ability to non-invasively detect and track deposition of individual particulates in live mouse airways. With further refinement of particulate sizing and delivery techniques, PCXI should provide a novel approach for live animal monitoring of airway particulates relevant to lung health.
Keywords: particles
non-invasive
airway surface
X-ray phase contrast
asbestos
mouse
detection
X-ray imaging
radiography.
DOI: 10.1107/S0909049509012618
Published version: http://dx.doi.org/10.1107/s0909049509012618
Appears in Collections:Aurora harvest 5
Paediatrics publications

Files in This Item:
File Description SizeFormat 
hdl_52134.pdfPublished version1.27 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.