Title: Preoperative use of ultrasonography to localize an ingested foreign body
Author: Piotto, L.
Gent, R.
Kirby, C.
Morris, L.
Citation: Pediatric Radiology: roentgenology, nuclear medicine, ultrasonics, CT, MRI, 2009; 39(3):299-301
Publisher: Springer-Verlag
Issue Date: 2009
ISSN: 0301-0449
1432-1998
Statement of
Responsibility: 
Lino Piotto, Roger Gent, Christopher P. Kirby and Lloyd L. Morris
Abstract: We report a 9-year-old boy who had swallowed a small dressmaker’s pin during an art & craft class. Confirmation of ingestion of the pin and its passage through the gut was achieved with abdominal radiography. When the pin had not passed after 8 days, and with increasing concern about the likelihood of perforation, US was used to locate its exact position to allow surgical removal. This case report illustrates the unique use of US to reveal the intraappendiceal location of an ingested foreign body, facilitating its surgical removal.
Keywords: Ingested foreign body
Pin
Ultrasound
Child
Description: The original publication can be found at www.springerlink.com