General anesthesia with an injectable 8% v/v sevoflurane lipid emulsion administered intravenously to dogs

Date

2016

Authors

Natalini, C.
Da Silva Serpa, P.
Cavalcanti, R.
Polydoro, A.
Griffith, J.
Santos, L.
Nicholson, A.

Editors

Advisors

Journal Title

Journal ISSN

Volume Title

Type:

Journal article

Citation

Veterinary Anaesthesia and Analgesia, 2016; 43(3):271-280

Statement of Responsibility

Claudio C Natalini, Priscila B Da Silva Serpa, Ruben L Cavalcanti, Alexandre S Polydoro, Joanna E Griffith, Luiz CP Santos, and Anthony Nicholson

Conference Name

Abstract

Objective: To evaluate the potential of an intravenous (IV) sevoflurane formulation for maintenance of general anesthesia in dogs. Study design: Prospective crossover design. Animals: Six healthy, mature, mixed-breed dogs, four males and two females, weighing 11.7 ± 3.4 kg. Methods: Anesthesia was induced and maintained with propofol IV for instrumentation. Baseline measurements were recorded before administration of either sevoflurane in oxygen (Sevo-Inh) or lipid-emulsified sevoflurane 8% v/v in 30% Intralipid IV (Sevo-E), 0.5 mL kg−1 over 5 minutes followed by an infusion at 0.1–0.3 mL kg−1 minute−1. Dogs were breathing spontaneously. The ‘up-and-down’ technique was used to determine the minimum alveolar concentration (MAC) of sevoflurane. Over 120 minutes, a tail clamp was applied every 15 minutes and sevoflurane administration was adjusted depending on the response. End-tidal sevoflurane concentration and variables were recorded at 30, 60, 90, and 120 minutes: heart rate (HR), systemic arterial pressure (sAP), respiratory rate (fR), end-tidal carbon dioxide tension, hemoglobin oxygen saturation (SaO2), arterial pH and blood gases, blood urea nitrogen, alanine aminotransferase, creatine kinase, gamma-glutamyl transferase, and aspartate aminotransferase. Results: There were no significant differences between treatments for HR, sAP, fR, SaO2, and biochemical variables (p > 0.05). pH and inline imagewere significantly decreased, and PaCO2 increased from baseline in Sevo-E (p < 0.05). MAC was significantly lower for Sevo-E than for Sevo-Inh, although the required dose of sevoflurane (g hour−1) to maintain general anesthesia was not significantly different between treatments. Conclusions and clinical relevance: Administration of 8% v/v sevoflurane lipid emulsion IV was effective in maintaining general anesthesia in dogs, but resulted in moderate cardiopulmonary depression, metabolic and respiratory acidosis. The amount of sevoflurane (g hour−1) required to maintain general anesthesia was significantly lower for inhaled than for IV sevoflurane.

School/Discipline

Dissertation Note

Provenance

Description

Access Status

Rights

© 2015 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia

License

Grant ID

Call number

Persistent link to this record