Use of the Vector TM scaling unit in supportive periodontal therapy: a subjective patient evaluation

dc.contributor.authorHoffmann, A.
dc.contributor.authorMarshall, R.
dc.contributor.authorBartold, P.
dc.date.issued2005
dc.descriptionCopyright © 2005 Blackwell Munksgaard The definitive version is available at www.blackwell-synergy.com
dc.description.abstractBackground: Patient discomfort is one reason for poor compliance with supportive periodontal therapy (SPT). The aim of this study was to compare the levels of discomfort during SPT, using the Vectort system and treatment with a conventional ultrasonic scaler. Methods: Forty-six patients with an SPT programme were debrided using both the Vectort system and a conventional piezo-electric scaler (Sironat) in a split mouth design. A visual analogue scale was used to evaluate of pain scores upon completion of treatment. A verbal response scale(VRS) was used to assess discomfort, vibration and noise associated with the scaling system, as well as the volume and taste of the coolant used by these systems. Results: Patients instrumented with the Vectort system experienced approximately half the amount of pain compared with the conventional ultrasonic scaling system. The VRS showed that the Vectort system caused less discomfort than the conventional ultrasonic scaling system when assessed for pain, vibration, noise and volume of coolant. These findings were all statistically significant. There was, however, no statistically significant difference between the two systems when assessed for taste. Conclusion: During SPT the Vectort system caused reduced discomforting sensations compared with conventional methods and may be useful in improving compliance with SPT programmes.
dc.description.statementofresponsibilityA. Hoffman, R. I. Marshall and P. M. Bartold
dc.identifier.citationJournal of Clinical Periodontology, 2005; 32(10):1089-1093
dc.identifier.doi10.1111/j.1600-051X.2005.00794
dc.identifier.issn0303-6979
dc.identifier.issn1600-051X
dc.identifier.orcidBartold, P. [0000-0002-5695-3877] [0000-0002-6225-3084]
dc.identifier.urihttp://hdl.handle.net/2440/16784
dc.language.isoen
dc.publisherBlackwell Munksgaard
dc.source.urihttps://doi.org/10.1111/j.1600-051x.2005.00794.x
dc.subjectpatient comfort
dc.subjectsupportive periodontal therapy
dc.subjectultrasonic scaler
dc.titleUse of the Vector TM scaling unit in supportive periodontal therapy: a subjective patient evaluation