Seismic behavior and design of reinforced concrete columns confined with FRP stay-in-place formwork

Date

2008

Authors

Saatcioglu, M.
Ozbakkaloglu, T.
Elnabelsy, G.

Editors

Advisors

Journal Title

Journal ISSN

Volume Title

Type:

Journal article

Citation

ACI Structural Journal, 2008; 257:149-170

Statement of Responsibility

M. Saatcioglu, T. Ozbakkaloglu, and G. Elnabelsy

Conference Name

Abstract

One of the applications of fiber-reinforced polymers (FRP) in building and bridge construction is stay-in-place formwork. FRP stay-in-place formwork, in the form of preformed tubes, provides easy form assembly protection of steel reinforcement and concrete against corrosion and chemical attacks while also improving the strength and ductility of structural elements in earthquakeresistant construction. Seismic performance of FRP tubes in building and bridge columns has been investigated through tests of large-scale specimens under simulated seismic loading. The experimental program consisted of tests of circular and square columns confined with carbon FRP (CFRP) tubes. The results indicate that the use of CFRP tubes increases column inelastic deformability significantly. Bridge columns under low levels of axial compression exhibit inelastic drift capacities in excess of 4% before failing in flexural tension due to the rupturing of longitudinal reinforcement. Building columns under higher levels of axial compression show drift capacities in excess of 8% when the behavior is governed by confined concrete. These observations and experimental results were used to develop a displacement-based design procedure for concrete confinement for FRP-encased concrete columns. The paper presents an overview of the experimental program and the design approach developed.

School/Discipline

Dissertation Note

Provenance

Description

Access Status

Rights

© Copyright 2010, American Concrete Institute

License

Grant ID

Published Version

Call number

Persistent link to this record