Mathematical analysis of occlusal rest design for cast removable partial dentures
Date
2007
Authors
Luk, N.
Wu, V.
Liang, B.
Chen, Y.
Yip, K.
Smales, R.
Editors
Advisors
Journal Title
Journal ISSN
Volume Title
Type:
Journal article
Citation
European Journal of Prosthodontics and Restorative Dentistry, 2007; 15(1):29-32
Statement of Responsibility
Conference Name
Abstract
AIMS: To establish the minimum dimensions for a non-precious cast metal occlusal rest by using mathematical analysis. An occlusal rest in a removable partial denture (RPD) provides vertical support and allows occlusal forces to be transmitted through the long axis of the abutment tooth. METHODS: The stress status of an occlusal rest in a posterior tooth-bounded RPD resembles that of a cantilever beam under a uniformly distributed load. A mathematical model based on a short rectangular cantilever beam was derived by using the yield strengths of a cast cobalt-chromium alloy and a cast titanium alloy (Ti-6Al-4V), with an applied static occlusal force of 400 N. RESULTS: For the cobalt-chromium alloy, the minimum rectangular dimensions for a 2.0 mm long occlusal rest are; when the width is 2.0 mm, the depth or thickness should be at least 1.03 mm. For the titanium alloy, the minimum dimensions are; when the width is 2.0 mm, the depth or thickness should be at least 0.85 mm. A decrease in the occlusal width will increase the bending stress, requiring a thicker rest for compensation, which may lead to dentin exposure during the rest seat preparation. CONCLUSION: The mathematical analysis found that the traditional spoon-shaped occlusal rest seat dimensions comply with the mechanical requirements for non-precious cast metal occlusal rests in RPDs.