Airbag testing of multi-leaf unreinforced masonry walls subjected to one-way bending

dc.contributor.authorDerakhshan, H.
dc.contributor.authorGriffith, M.
dc.contributor.authorIngham, J.
dc.date.issued2013
dc.description.abstractSix full-scale unreinforced masonry (URM) walls were built and tested to studythe post-cracking out-of-plane behavior of walls in the upper two or three stories of URM buildings. The one-way spanning two-leaf (230. mm nominal thickness) or three-leaf (350. mm nominal thickness) walls had variable heights from 2000. mm to 4100. mm and were subjected to one-way out-of-plane bending using a system of airbags. Initial testing was performed on each wall with zero overburden load applied, resulting in wall cracking and the development of post-cracking displacements of up to approximately 70% of the wall thickness. Four walls were re-tested in the cracked conditions but with overburden loads applied. It was found that analytical predictions underestimated the wall crack height by 16%, on average, and that the initial uncracked wall strength predictions were within 24% of the experimental measurements. It was also found that the maximum cracked wall resistance was, on average, 83% of the predicted value based upon the mechanics of rigid body rocking. An empirical relationship was proposed to account for the increase in the initial stiffness of the cracked walls due to the applied overburden. © 2013 Elsevier Ltd.
dc.description.statementofresponsibilityHossein Derakhshan, Michael C. Griffith, Jason M. Ingham
dc.identifier.citationEngineering Structures, 2013; 57:512-522
dc.identifier.doi10.1016/j.engstruct.2013.10.006
dc.identifier.issn0141-0296
dc.identifier.issn1873-7323
dc.identifier.orcidDerakhshan, H. [0000-0003-1859-4700]
dc.identifier.orcidGriffith, M. [0000-0001-9010-3764]
dc.identifier.urihttp://hdl.handle.net/2440/81636
dc.language.isoen
dc.publisherElsevier Sci Ltd
dc.rights© 2013 Elsevier Ltd.
dc.source.urihttps://doi.org/10.1016/j.engstruct.2013.10.006
dc.subjectBrick masonry
dc.subjectWalls
dc.subjectFull-scale tests
dc.subjectExperimentation
dc.subjectFlexural strength
dc.subjectLateral loads
dc.subjectAxial loads
dc.subjectStiffness
dc.titleAirbag testing of multi-leaf unreinforced masonry walls subjected to one-way bending