Scaling up capacity of stand-alone adsorption refrigeration tubes

Date

2019

Authors

Chen, E.
Wu, X.
Zhao, Y.
Hu, E.
Torres, J.F.

Editors

Advisors

Journal Title

Journal ISSN

Volume Title

Type:

Journal article

Citation

Results in Engineering, 2019; 4:100066-1-100066-3

Statement of Responsibility

Ersong Chen, Xiaoquan Wu, Yongling Zhao, Eric Hu, Juan F. Torres

Conference Name

Abstract

On the basis of a validated model, a parametric study is conducted to understand the effects of operating parameters on the coefficient of performance (COP) and specific cooling power (SCP) of a stand-alone adsorption refrigeration tube (ART). It is revealed that the SCP obtained based on the model with the transient pressure process (TPP) boundary condition is approximately 20% higher than that obtained without the TPP. A scaling up solution of using multiple ARTs to produce continuous cooling is also proposed and discussed.

School/Discipline

Dissertation Note

Provenance

Description

Access Status

Rights

© 2019 Published by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).

License

Call number

Persistent link to this record