Wear of a highly cross-linked polyethylene liner: a preliminary RSA study
dc.contributor.author | Campbell, D. | |
dc.contributor.author | Mercer, G. | |
dc.contributor.author | Nilsson, G. | |
dc.contributor.author | Wells, V. | |
dc.contributor.author | Field, J. | |
dc.contributor.author | Callary, S. | |
dc.date.issued | 2009 | |
dc.description.abstract | Wear induced peri-prosthetic osteolysis and aseptic loosening remain the major contributing factors to failure of total hip arthroplasty. To reduce wear particles from acetabular liners, the process of polyethylene cross-linking has been modified. In this study, we examine the wear of Marathon™ acetabular liners using Radiostereometric Analysis. Thirty patients were enrolled in a prospective cohort study. Femoral head penetration was calculated for 25 patients at 6 months, 1 and 2 years postoperatively. The mean proximal head penetration was 0.067 mm at 6 months, 0.113 mm at 1 year and 0.120 mm at 2 years. The mean three-dimensional femoral head penetration was 0.240 mm at 6 months, 0.230 mm at 1 year and 0.232 mm at 2 years. For both parameters, there was no measurable wear between 1 and 2 years, and the mean annual linear wear was less than 0.06 mm/year, which is less than the suggested osteolysis threshold for polyethylene. All patients demonstrated a dramatic improvement in clinical scores. These results were comparable with other studies that used alternative techniques with conventional radiography to evaluate wear for Marathon™. Long-term studies using the RSA method are recommended to further quantify the clinical performance of this polyethylene liner. | |
dc.description.statementofresponsibility | David Campbell, Graham Mercer, Kjell-Gunnar Nilsson, Vanessa Wells, John R. Field and Stuart A. Callary | |
dc.identifier.citation | European Journal of Orthopaedic Surgery and Traumatology, 2009; 20(1):23-27 | |
dc.identifier.doi | 10.1007/s00590-009-0486-y | |
dc.identifier.issn | 1633-8065 | |
dc.identifier.issn | 1432-1068 | |
dc.identifier.orcid | Campbell, D. [0000-0002-1572-9529] | |
dc.identifier.orcid | Callary, S. [0000-0002-2892-5238] | |
dc.identifier.uri | http://hdl.handle.net/2440/57168 | |
dc.language.iso | en | |
dc.publisher | Springer France | |
dc.source.uri | https://doi.org/10.1007/s00590-009-0486-y | |
dc.subject | Hip | |
dc.subject | Wear | |
dc.subject | RSA | |
dc.subject | Polyethylene | |
dc.subject | Radiostereometric analysis | |
dc.subject | Cross-linked | |
dc.title | Wear of a highly cross-linked polyethylene liner: a preliminary RSA study | |
dc.type | Journal article | |
pubs.publication-status | Published |