A multicenter study to evaluate harmonization of assays for N-terminal propeptide of type i procollagen (PINP): a report from the IFCC-IOF Joint Committee for Bone Metabolism

Date

2019

Authors

Cavalier, E.
Eastell, R.
Rye Jørgensen, N.
Makris, K.
Tournis, S.
Vasikaran, S.
Kanis, J.A.
Cooper, C.
Pottel, H.
Morris, H.A.

Editors

Advisors

Journal Title

Journal ISSN

Volume Title

Type:

Journal article

Citation

Clinical Chemistry and Laboratory Medicine, 2019; 57(10):1546-1555

Statement of Responsibility

Etienne Cavalier, Richard Eastell, Niklas Rye Jørgensen, Konstantinos Makris, Symeon Tournis ... Howard A. Morris ... et al.

Conference Name

Abstract

Background Biochemical bone turnover markers (BTM) are useful tools to assess bone remodeling at the cellular level. N-terminal propeptide of type I procollagen (PINP) has been recommended as a reference marker for bone formation in research studies. Methods We describe the results of a multicenter study for routine clinical laboratory assays for PINP in serum and plasma. Four centers (Athens, Greece [GR], Copenhagen, Denmark [DK], Liege, Belgium [BE] and Sheffield, United Kingdom [UK]) collected serum and plasma (EDTA) samples from 796 patients presenting to osteoporosis clinics. Specimens were analyzed in duplicate with each of the available routine clinical laboratory methods according to the manufacturers' instructions. Passing-Bablok regressions, Bland-Altman plots, V-shape evaluation method and the concordance correlation coefficient for PINP values between serum and plasma specimens and between methods were used to determine the agreement between results. A generalized linear model was employed to identify possible variables that affected the relationship between the methods. Results We showed that both EDTA plasma and serum were suitable for PINP determination. We observed a significant proportional bias between Orion radioimmunoassay and the automated methods for PINP (Roche Cobas and IDS iSYS), which both gave very similar results. The multivariate model did not improve the excellent correlation that was observed between the methods. Conclusions Harmonization of PINP assays is possible by applying a correction factor or correctly assigning the values of the calibrators. This work will benefit from further collaboration between assays manufacturers and clinical laboratory professionals.

School/Discipline

Dissertation Note

Provenance

Description

Published online: 14 May 2019

Access Status

Rights

©2019 Walter de Gruyter GmbH, Berlin/Boston.

License

Grant ID

Call number

Persistent link to this record