Transcranial doppler ultrasound to assess cerebrovascular reactivity: reliability, reproducibility and effect of posture

dc.contributor.authorMcDonnell, M.
dc.contributor.authorBerry, N.
dc.contributor.authorCutting, M.
dc.contributor.authorKeage, H.
dc.contributor.authorBuckley, J.
dc.contributor.authorHowe, P.
dc.date.issued2013
dc.descriptionPublished 9 April 2013
dc.description.abstractTranscranial Doppler ultrasound (TCD) allows measurement of blood flow velocities in the intracranial vessels, and can be used to assess cerebral vasodilator responses to a hypercapnic stimulus. The reliability of this technique has not been established, nor is there agreement about whether the technique should be performed in sitting or lying postures. We tested the intra- and inter-rater reliability of measures of cerebrovascular reactivity (CVR) in 10 healthy adults, in sitting and lying postures. Participants underwent triplicate bilateral ultrasound assessment of flow velocities in the middle cerebral arteries whilst sitting and lying supine prior to and during inhalation of Carbogen (5% CO2, 95% O2) for 2 min. This procedure was performed twice by each of two raters for a total of four sessions. CVR was calculated as the difference between baseline and the peak blood flow velocity attained during CO2 inhalation. Intraclass correlation coefficients (ICCs) for intra-rater reliability were greater sitting than lying for both raters (e.g. Rater 1 ICC sitting = 0.822, lying = 0.734), and inter-rater reliability was also greater in sitting (e.g. sitting ICC = 0.504, lying = 0.081). These results suggest that assessment of CVR using TCD should be performed with participants sitting in order to maximise CVR measurement reliability.
dc.description.statementofresponsibilityMichelle N. McDonnell, Narelle M. Berry, Mark A. Cutting, Hannah A. Keage, Jonathan D. Buckley and Peter R.C. Howe
dc.identifier.citationPeerJ, 2013; 1(1):e65-1-E65-11
dc.identifier.doi10.7717/peerj.65
dc.identifier.issn2167-8359
dc.identifier.issn2167-8359
dc.identifier.orcidKeage, H. [0000-0002-6814-4997]
dc.identifier.orcidHowe, P. [0000-0001-6546-7742]
dc.identifier.urihttp://hdl.handle.net/2440/113001
dc.language.isoen
dc.publisherPeerJ
dc.relation.grantNHMRC
dc.rightsCopyright 2013 McDonnell et al. Distributed under Creative Commons CC-BY 3.0
dc.source.urihttps://doi.org/10.7717/peerj.65
dc.subjectReliability
dc.subjectReproducibility
dc.subjectCerebrovascular reactivity
dc.subjectPosture
dc.subjectDoppler ultrasound
dc.titleTranscranial doppler ultrasound to assess cerebrovascular reactivity: reliability, reproducibility and effect of posture
dc.typeJournal article
pubs.publication-statusPublished

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
hdl_113001.pdf
Size:
565.99 KB
Format:
Adobe Portable Document Format
Description:
Published version