Influence of surface roughness and shape on microdamage of the osseous surface adjacent to titanium dental implants

Date

2011

Authors

Bartold, P.
Kuliwaba, J.
Lee, V.
Shah, S.
Marino, V.
Fazzalari, N.

Editors

Advisors

Journal Title

Journal ISSN

Volume Title

Type:

Journal article

Citation

Clinical Oral Implants Research, 2011; 22(6):613-618

Statement of Responsibility

P. M. Bartold, J. S. Kuliwaba, V. Lee, S. Shah, V. Marino, N. L. Fazzalari

Conference Name

Abstract

Objectives: To assess the relationship between smooth and roughened implant surfaces of straight and narrow configurations with respect to microdamage of the bone surface during placement of dental implants Materials and methods: Straight and tapered, rough and smooth surface Nobel Biocare implants were placed into sheep mandibles. Microdamage within the bone adjacent to the implant surface was quantitated using a semi-automated digitized histomorphometric method. Results: Independent of implant type, microdamage, microcracks, cross-hatch damage and diffuse damage were significantly higher close to the implants compared with far from the implants. Microcracks and cross-hatch damage were higher for the rough cylindrical implants than all the other implant types. Conclusions: Insertion of a rough cylindrical implant type results in an increased fraction of microdamaged bone matrix in comparison to rough tapered, smooth cylindrical and smooth tapered implants.

School/Discipline

Dissertation Note

Provenance

Description

Access Status

Rights

© 2010 John Wiley & Sons A/S

License

Grant ID

Call number

Persistent link to this record